Lucent Technologies Comcode 108678723 Gain/Loss adjustments, None , lan , man , wan , and custom

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 129
Image 129

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

5Administering ATM-PNC and ATM-CES

Administering DEFINITY ECS

 

5-31

Field description:

 

 

Algorithm

The name of the cache algorithm (default is lan). Possible values are

 

none, lan, man, wan, and custom.

 

When this field is changed to none, lan, man, or wan, the read-only For

 

Latency and Hold Time field values change to the following (all other

 

entries are blank):

 

 

Value

For Latency (ms)

Hold Time (ms)

 

none

0

0

 

lan

50

36

 

 

0

12

 

man

800

80

 

 

50

16

 

 

0

8

 

wan

800

200

 

 

200

36

 

 

50

16

 

 

0

0

 

When this field is custom, none of the For Latency or Hold Time field

 

values change, but the fields change from read-only to read/write. For

 

example, if you want a slight variation of the wan algorithm, type wan first

 

to set the above values, then type custom to change the individual

 

parameters.

 

 

Size

The maximum number of entries simultaneously allowed in the cache

 

(default = 410).

 

For Latency

These fields (10) are read-only if the Algorithm field is none, lan, man,

 

or wan, but are read/write if Algorithm is custom. Defaults: 36 for the

 

1st entry, 0 for the second, blank for the last 8 entries.

Gain/Loss adjustments

Gain and loss are administrable. Calls between a digital (BRI or DCP) phone (6400 and 8400 series) and an analog trunk port require adjustments to the default gain/loss settings to prevent distortion. Use the procedure (Table 5-12) to administer digital phones on ATM-PNC DEFINITY ECSs.

NOTE:

Use the following procedure only for Series 6400 or 8400 digital phones.

Page 129
Image 129
Lucent Technologies Comcode 108678723 manual Gain/Loss adjustments, None , lan , man , wan , and custom