Lucent Technologies Comcode 108678723 manual Screen 6-3. Screen output for list atm pnc command

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 158
Image 158

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

6 Troubleshooting

 

Troubleshooting ATM-PNC

6-24

 

 

list atm pnc

 

Page 1 SPE A

 

 

ATM PNC

PNC

A-PNC

B-PNC

Connection #

LOC

LOC

1

01B02

 

2

02A01

 

 

 

 

Screen 6-3. Screen output for list atm pnc command

Alternatively, type list configuration UUC and press Enter (noncontrol cabinets) to confirm the PPN and EPN circuit pack locations and correct insertion.

2.Type status pnc and press Enter. This display tells you which TN2305/TN2306 circuit pack is active in a duplicated system and how many alarms (if any) of each severity level have been logged for the circuit pack. Screen 6-4 shows the output from this command.

status pnc

PORT NETWORK CONNECTIVITY

Duplicated? no

Software Locked?

Standby Busied?

Standby Refreshed?

Interchange Disabled?

A-PNC

B-PNC

Mode: active

Mode:

State of Health: functional

State of Health:

Inter PN Index: 00.00.00

Inter PN Index:

Major Alarms: 0

Major Alarms:

Minor Alarms: 0

Minor Alarms:

Warning Alarms: 0

Warning Alarms:

Screen 6-4. Screen output for status pnc command

3.Type either list configuration UUC (for the carrier in which the ATM interface circuit packs reside) or display circuit-packscabinet (noncontrol cabinet) and press Enter. This command tells you in more detail what boards are in which slots in each cabinet and carrier. Verify that the TN2305/TN2306s are physically located in the slots indicated on the display. Screen 6-5 shows the output for the display circuit-packs 1 command; Screen 6-6 shows the output for the display circuit-packs 2 command.

Page 158
Image 158
Lucent Technologies Comcode 108678723 manual Screen 6-3. Screen output for list atm pnc command