3 Installing a DEFINITY ECS ATM-PNC

 

Synchronization Installation and Testing

3-21

 

 

Connected through an ICSU. Use the procedures in Table 3-9 to install the splitter between an ICSU and a DS1 circuit pack.

Table 3-9. Installing the splitter through an ICSU

 

Step

Action

Command

Description

 

 

 

 

 

 

 

 

 

 

1.

Disable

disable

Prevent the system from switching synchronization

 

 

 

 

synchronization

synchronization

sources.

 

 

 

 

switch

-switch

 

 

 

 

 

 

 

 

 

 

 

2.

Busyout DS1

busyout board

Busyout the designated DS1circuit pack.

 

 

 

 

circuit pack

UUCSS

 

 

 

 

 

 

 

 

 

 

 

3.

Remove cable

 

Remove the existing H600-307 cable from the backplane

 

 

 

 

from DS1 circuit

 

slot corresponding to the designated DS1 circuit pack.

 

 

 

 

pack

 

 

 

 

 

 

 

 

 

 

 

 

4.

Remove ICSU

 

Remove the ICSU from the designated DS1 circuit pack’s

 

 

 

 

 

 

amphenol connector.

 

 

 

 

 

 

Re-use the existing cable attached to the ICSU.

 

 

 

 

 

 

 

 

 

 

5.

Attach splitter

 

Plug the splitter into the same connector just vacated by

 

 

 

 

 

 

the ICSU.

 

 

 

 

 

 

 

 

 

 

6.

Attach ICSU

 

Plug the ICSU into the connector on the splitter.

 

 

 

 

 

 

 

 

 

 

7.

Reconnect

 

Connect the H600-307 cable to the amphenol connector

 

 

 

 

cable

 

on the ICSU.

 

 

 

 

 

 

 

 

 

 

8.

Check

 

Check that all Amphenol connections are good.

 

 

 

 

connections

 

 

 

 

 

 

 

 

 

 

 

 

9.

Secure splitter

 

Secure the splitter to the carrier using the 4C retainer from

 

 

 

 

 

 

the ICSU.

 

 

 

 

 

 

 

 

 

 

10.

Secure ICSU

 

Secure the ICSU to the splitter with a long cable tie.

 

 

 

 

 

 

 

 

 

 

11.

Terminate the

 

Insert a modular RJ45 plug in both ports J1 and J2. Do not

 

 

 

 

splitter ports J1

 

connect port J1 to port J2, but leave the other end of both

 

 

 

 

and J2

 

cords free. The modular RJ45 plug acts as an opening

 

 

 

 

 

 

plug and removes the 100-Ωtermination from port J1 and

 

 

 

 

 

 

J2 on the splitter.

 

 

 

 

 

 

 

 

 

 

12.

Check DS1

 

After about 20 seconds the LEDs on the DS1 circuit pack

 

 

 

 

Status 3 LED

 

should go out, leaving only the GREEN STATUS 3 LED on.

 

 

 

 

 

 

 

 

 

 

13.

Test the DS1

test board

Test the circuit pack.

 

 

 

 

circuit pack

UUCSS

If any one of Tests 138 - 145 fails, follow the repair

 

 

 

 

 

 

 

 

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r

 

 

 

 

 

 

 

 

 

 

14.

Clear the error

clear

Clear the error events counter.

 

 

 

 

events counters

measurements

 

 

 

 

 

 

ds1

 

 

 

 

 

 

esf-error-events

 

 

 

 

 

 

UUCSS

 

 

 

 

 

 

 

 

 