SYSTEM PARAMETERS COUNTRY-OPTIONS

 

 

 

Companding Mode: Mu-Law

 

Base Tone Generator Set: 1

 

 

440Hz PBX-dial Tone?

n

 

440Hz Secondary-dial Tone? n

 

 

Digital Loss Plan: 1

 

 

 

 

 

Analog Ringing Cadence: 1

Set Layer 1 timer T1 to 30 seconds? n

 

 

Analog Line Transmission: 1

 

 

 

 

 

64/84xx Display Character Set? roman

 

 

 

 

 

TONE DETECTOR PARAMETERS

 

 

 

 

 

 

Tone Detection Mode: 6

 

 

 

 

 

Interdigit Pause: short

 

 

 

 

 

 

 

 

Screen 5-16. System parameters country-options—screen 1

 

 

 

change terminal-parameters 6400

 

 

Page 1 of

1 SPE A

 

6400-TYPE TERMINAL PARAMETERS

 

 

 

Default Parameter Set: 1

 

Customize Parameters? y

 

 

OPTIONS

 

Display Mode:

 

Handset Expander Enabled?

 

Volume:

 

PRIMARY LEVELS

 

Voice Transmit (dB): 2.5

 

Voice Receive (dB): 2.5

 

Voice Transmit (dB):

Voice Sidetone (dB):

Touch Tone Transmit (dB):

 

Voice Receive (dB):

Touch Tone Sidetone (dB):

BUILT-IN SPEAKER LEVELS

 

Voice Transmit (dB):

Voice Receive (dB):

 

Touch Tone Sidetone (dB):

6402 BUILT-IN SPEAKER LEVELS

 

Voice Receive (dB):

Touch Tone Sidetone (dB):

Screen 5-17. 6400-type terminal parameters