GAS INSTRUCTIONS
Check
A) Main gas line to manifold connection (1)..
B) Rotisserie (I..R.. Burner) gas line connection (2)..
C) Bulkhead and gas supply hose connection (3)..
D) Bulkhead to regulator connection (4)..
E) Regulator to hose connection (5)..
F) Side burner hose to bulkhead connection (6)..
m WARNING: If there is a leak at connection (1, 2, 3, 4, 5, or 6), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after
Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
G)Side burner hose to quick disconnect connection, side burner valve and orifice connections (7)..
H) Hose to quick disconnect connection (8)..
I)Valves to manifold connections (9)..
mWARNING: If there is a leak at connections (7, 8, or 9), turn off the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
When leak checks are complete, turn gas supply off at the source and rinse connections with water..
Reinstall Control Panel
Parts required: control panel, screws and burner control knobs..
A) Hook the top edge of the control panel onto the control panel brackets on either side of the front of the cookbox..
B)Line up screws with screw holes on both the control panel bracket and the frame..
C)Tighten screws..
D) Place corresponding control knobs onto the valve stems.. ◆
9