14
VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.)
VENTING INSTALLATION
INSTRUCTIONS
Continued
Venting with One 90° Elbow
Vertical (V) | Horizontal (H) |
5' min. | 2' max. |
6' min. | 4' max. |
7' min. | 6' max. |
8' min. | 8' max. |
20' max. | 8' max. |
45° Elbow | Note: Install restrictor |
| into inner collar of |
| fireplace as shown. |
Figure 22 - Vertical Venting Configuration Using One 90° Elbow
(Vertical Round High Wind Termination Shown)
Venting with Two 90° Elbows | 45° Elbow | |
|
| |
Vertical (V1) | Horizontal (H) |
|
5' min. | 6' max. |
|
6' min. | 12' max. |
|
7' min. | 18' max. |
|
8' min. | 20' max. |
|
Vertical Venting
V = 40' max.
Note: Install restrictor into inner collar of fireplace as shown.
Note: Install restrictor into inner collar of fireplace as shown.
45° Elbow
Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)
Note: Vertical (V1) + Vertical (V2) = 40' max.
Figure 23 - Vertical Venting Configuration Using Two 90° Elbows (Vertical Round High Wind Termination Shown)