24
OPERATING FIREPLACE
Lighting Instructions
To Turn Off Gas To Appliance
Optional Remote Operation
Operating Optional Blower Accessory
OPERATING FIREPLACE | |
Continued | |
| LIGHTING |
| INSTRUCTIONS |
|
|
| NOTICE: During initial operation of new heater, burn- |
| ing logs will give off a |
| flame will also be present. Open damper or window |
| to vent smell. This will only last a few hours. |
|
|
1. | STOP! Read the safety information, page 23. |
2. | Turn off all electric power to the appliance. |
3. | Turn wall switch to the OFF position. |
4.Open lower louver panel.
5.Turn equipment shutoff valve clockwise to the OFF position (see Figure 48). Do not force.
6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in page 23. If you donʼt smell gas, go to the next step.
7.Turn equipment shutoff valve counterclockwise to the ON position. Do not force.
8. | Close lower louver panel. |
9. | Turn on all electric power to the appliance. |
10. | Turn the wall switch to the ON position. |
11.Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot.
•If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners.
•If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier.
Equipment | Pilot | |
Adjustment | ||
Shutoff | ||
Screw | ||
Valve | ||
|
Figure 48 - Turning Equipment Shutoff Valve to the OFF Position
| TO TURN OFF GAS |
|
| TO APPLIANCE |
|
1. | Turn off the wall switch. |
|
2. | Turn off all electric power to the appliance if service is to | |
| be performed. |
|
3. | Open lower louver panel. |
|
4. | Remove front hearth brick and control access panel. | |
5. | Turn equipment shutoff valve clockwise | to OFF. |
| Do not force. |
|
6. | Close lower louver panel. |
|
Pilot Burner | Sensing Rod |
| |
Ignitor |
|
Figure 49 - Pilot |
|
OPTIONAL REMOTE | |
OPERATION |
|
Note: The WRC receiver and | |
must be purchased separately (see Accessories, page 34). Follow | |
installation instructions on page 23. |
|
1.Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the
2.Press the ON/OFF button to turn the burner on and off.
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the right just inside the louver panel.
The BK manual blowerand the
Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time.The fireplace may run forseveral minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Peri- odically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.
www.desatech.com |