CLEANING AND MAINTENANCE

Glass Door (Cont.)

Pilot and Burners

Logs

Venting System

CLEANING AND

MAINTENANCE

Continued

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 29 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 20 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs, Lava Rock and Glowing Embers, page 21, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 29.

Replace ember material periodically as needed. See Replacement Parts on page 29.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

www.desatech.com

116647-01A

Image 26
Contents Save this manual for future reference For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationAny wall. This will cause a fire hazard Vent Pipe ConnectionsConnecting Vent Cap with Horizontal Vent Pipe Horizontal Termination Configurations Venting InstallationInstructions Vertical Horizontal H20 max Max Venting with Two 90 ElbowsHorizontal H Vertical Min Max 12 max 18 max 20 max Vertical Horizontal H Min Max 12 max 18 max 20 max Installation for Vertical TerminationHorizontal H 1 + Vertical V Horizontal H1 + Horizontal H2 Min Max 20 max Flat Ceiling InstallationVertical Termination Configurations Vertical V Horizontal H Min Max 12 max 18 max 20 max Venting with One 90 ElbowVertical Horizontal H Min Max 20 max Vertical VentingNumber Description High Altitude InstallationDesa 5/8 Pipe & Vent Kits Fireplace Installation Check GAS Type Installing Optional Blower AccessoryBlower Wiring Diagram Fireplace InstallationModel BKT Installation Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door Removing Glass DoorInstalling Optional Brick Liner Model BL32D Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Optional Remote Control Wiring DiagramWall Switch Installation For Your Safety Read Before LightingTo Turn OFF GAS To Appliance Operating Optional Blower AccessoryLighting Optional RemoteInspecting Burners Cleaning MaintenancePilot Assembly Glass DoorVenting System Pilot and BurnersLogs Troubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at TopTechnical Service Replacement PartsSpecifications Service Hints Parts Under WarrantyIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListBurner Assembly Models 109KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Warranty Information Keep this Warranty