Desa (V)T32EN-A Series, (V)T32EP-A Series Fireplace Installation Check GAS Type

Page 16

16

FIREPLACE INSTALLATION

Check Gas Type

Installing Optional Blower Accessory

FIREPLACE INSTALLATION CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 34).

INSTALLING OPTIONAL BLOWER

ACCESSORY

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation Follow all instructions provided in the blower accessory kit.

1.

Attach the power cord to the blower motor by firmly pushing the

 

two female terminals at the end of the power cord onto the two

 

spade terminals on the blower motor (see Figure 25).

2.

Attach green ground wire from power cord to blower hous-

 

provided (see Figure 25). Tighten screws

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 1.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox ownerʼs manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing.

10.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27).

 

ing using screw

 

securely.

3.

Place the blower against the lower rear wall of the firebox outer

 

wrapper with the exhaust port directed upward. The blower will

 

fit inside the back opening and be held in position against the

 

back wall by the magnets (see Figure 25).

4.

Be certain that all wire terminals are securely attached to ter-

 

minals on blower motor and that the screw retaining the green

 

ground wire is tight.

Switch

Bracket

Control

Knob

Locknut

Speed

Control

Blower

Plug-In

Control

Duplex Outlet

(Located underneath

Shaft

firebox floor against

 

 

lower right outside wall)

 

Blower

 

Location

 

Lower Firebox

 

Cavity

Side View

Magnetic Strips

 

Spade Terminals

Exhaust

 

Port

Green

 

Ground

Screw

Wire

 

Figure 25 - Blower Model BK

Figure 26 - Attaching Speed Control to Firebox

Wiring Diagram Decal

12" in Front of Blower

Figure 27 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

www.desatech.com

116647-01A

Image 16
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Table of Contents Safety InformationSafety Information Product Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationAny wall. This will cause a fire hazard Vent Pipe ConnectionsConnecting Vent Cap with Horizontal Vent Pipe Venting Installation InstructionsHorizontal Termination Configurations Vertical Horizontal HHorizontal H Vertical Min Max 12 max 18 max 20 max Venting with Two 90 Elbows20 max Max Horizontal H 1 + Installation for Vertical TerminationVertical Horizontal H Min Max 12 max 18 max 20 max Vertical Termination Configurations Flat Ceiling InstallationVertical V Horizontal H1 + Horizontal H2 Min Max 20 max Venting with One 90 Elbow Vertical Horizontal H Min Max 20 maxVertical V Horizontal H Min Max 12 max 18 max 20 max Vertical VentingDesa 5/8 Pipe & Vent Kits High Altitude InstallationNumber Description Fireplace Installation Check GAS Type Installing Optional Blower AccessoryModel BKT Installation Fireplace InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Glass DoorInstalling Optional Brick Liner Model BL32D Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Wiring Diagram Wall Switch InstallationOptional Remote Control For Your Safety Read Before LightingOperating Optional Blower Accessory LightingTo Turn OFF GAS To Appliance Optional RemoteCleaning Maintenance Pilot AssemblyInspecting Burners Glass DoorLogs Pilot and BurnersVenting System Troubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at TopReplacement Parts Specifications Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListBurner Assembly Models 109KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Warranty Information Keep this Warranty