INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

CLEANING AND MAINTENANCE

Glass Door

25

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Altera- tions may have occurred during shipping and handling. The pilot is located on the left hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 48, page 24). Do not remove the adjustment screw.

see Troubleshooting, page 27

Pilot Burner

Sensing Rod

 

 

Ignitor/Sensor

CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

Figure 50 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on instal- lation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after instal- lation to ensure proper installation and performance.

Figure 51 shows a typical flame pattern.

If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Appliance, page 24)

see Troubleshooting, page 27

Figure 51 - Typical Flame Pattern

WARNING: Do not use abrasive cleaners as this maydamageglass.Useanonabrasivehouseholdglass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circum- stances present. Refer to Removing/Replacing Glass Door on page 20 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manu- facturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 29). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION:Wearglovesandsafetyglasseswhilehan- dling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 20). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

116647-01A

www.desatech.com

Image 25
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Any wall. This will cause a fire hazardConnecting Vent Cap with Horizontal Vent Pipe Instructions Venting InstallationHorizontal Termination Configurations Vertical Horizontal HHorizontal H Vertical Min Max 12 max 18 max 20 max Venting with Two 90 Elbows20 max Max Horizontal H 1 + Installation for Vertical TerminationVertical Horizontal H Min Max 12 max 18 max 20 max Vertical Termination Configurations Flat Ceiling InstallationVertical V Horizontal H1 + Horizontal H2 Min Max 20 max Vertical Horizontal H Min Max 20 max Venting with One 90 ElbowVertical V Horizontal H Min Max 12 max 18 max 20 max Vertical VentingDesa 5/8 Pipe & Vent Kits High Altitude InstallationNumber Description Installing Optional Blower Accessory Fireplace Installation Check GAS TypeModel BKT Installation Fireplace InstallationBlower Wiring Diagram Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Cleaning Glass Door Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Model BL32DInstalling Logs No and No Wall Switch Installation Wiring DiagramOptional Remote Control For Your Safety Read Before LightingLighting Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance Optional RemotePilot Assembly Cleaning MaintenanceInspecting Burners Glass DoorLogs Pilot and BurnersVenting System Observed Problem Possible Cause Remedy TroubleshootingTop Gas leak. See Warning statement atSpecifications Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts List109 Burner Assembly ModelsKEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Keep this Warranty Warranty Information