SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

5.

This fireplace reaches high temperatures. Keep children and

 

adults away from hot surfaces to avoid burns or clothing igni-

 

tion. Fireplace will remain hot for a time after shutdown. Allow

 

surfaces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with fireplace.

7.

Do not modify this fireplace under any circumstances. Any

 

parts removed for servicing must be replaced prior to operating

 

fireplace.

8.

Turn fireplace off and let cool before servicing, installing or

 

repairing. Only a qualified service person should install, service

 

or repair this fireplace. Have fireplace inspected annually by a

 

qualified service person.

9.

You must keep control compartments, burners and circulating

 

air passages clean. More frequent cleaning may be needed due

 

to excessive lint and dust from carpeting, bedding material, etc.

 

Turn off the gas valve and pilot light before cleaning fireplace.

10.

Have venting system inspected annually by a qualified service

Upper Louver

Panel

Nailing

Flange

Glass

Door

Assembly

Lower

Louver

Panel

Flue Collar

Log Set

Lava

Rock

 

person. If needed, have venting system cleaned or repaired. See

 

Cleaning and Maintenance, page 25.

11. Keep the area around your fireplace clear of combustible ma-

 

terials, gasoline and other flammable vapor and liquids. Do

 

not run fireplace where these are used or stored. Do not place

 

items such as clothing or decorations on or around fireplace.

12.

Do not use this fireplace to cook food or burn paper or other

 

objects.

13.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this fireplace. Use only the gas type indicated on fireplace

 

nameplate.

14.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local

 

codes, with the National Electrical Code, ANSI/NFPA 70 or

 

the Canadian Electrical Code, CSA C22.1.

15.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service person to arrange

 

for replacement of the unit.

16.

Do not operate fireplace if any log is broken.

17.

Do not use a blower insert, heat exchanger insert or other ac-

 

cessory not approved for use with this fireplace.

18.

Do not operate fireplace with glass door removed, cracked or

 

broken.

19.

Provide adequate clearances around air openings.

Electronic

Glowing

Control Valve

Embers

Burner

 

Assembly

Switch Bracket for

 

 

Optional Remote and

 

Blower

Figure 1 - Direct-Vent Fireplace with Electronic Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

116647-01A

www.desatech.com

Image 3
Contents For Your Safety For Your Safety What to do if YOU Smell GASSave this manual for future reference Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Any wall. This will cause a fire hazardConnecting Vent Cap with Horizontal Vent Pipe Vertical Horizontal H Venting InstallationInstructions Horizontal Termination ConfigurationsVenting with Two 90 Elbows Horizontal H Vertical Min Max 12 max 18 max 20 max20 max Max Installation for Vertical Termination Horizontal H 1 +Vertical Horizontal H Min Max 12 max 18 max 20 max Flat Ceiling Installation Vertical Termination ConfigurationsVertical V Horizontal H1 + Horizontal H2 Min Max 20 max Vertical Venting Venting with One 90 ElbowVertical Horizontal H Min Max 20 max Vertical V Horizontal H Min Max 12 max 18 max 20 maxHigh Altitude Installation Desa 5/8 Pipe & Vent KitsNumber Description Installing Optional Blower Accessory Fireplace Installation Check GAS TypeFireplace Installation Model BKT InstallationBlower Wiring Diagram Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Removing Glass Door Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Model BL32DInstalling Logs No and No For Your Safety Read Before Lighting Wiring DiagramWall Switch Installation Optional Remote ControlOptional Remote Operating Optional Blower AccessoryLighting To Turn OFF GAS To ApplianceGlass Door Cleaning MaintenancePilot Assembly Inspecting BurnersPilot and Burners LogsVenting System Observed Problem Possible Cause Remedy TroubleshootingTop Gas leak. See Warning statement atParts Under Warranty Replacement PartsSpecifications Service Hints Technical ServiceIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts List109 Burner Assembly ModelsKEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Keep this Warranty Warranty Information