INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes)

*ACSAdesign-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

For propane/LP connection only, the installer must supply an ex- ternal regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet.

External

Propane/LP

Regulator

Supply Tank

Vent

Pointing

Down

Figure 30 - External Regulator with Vent Pointing Down (Propane/LP Only)

CAUTION: Use only new, black iron or steel

pipe. Internally-tinned copper tubing may be used in

certain areas. Check your local codes. Use pipe of

1/2" inside diameter or greater to allow proper gas

volume to fireplace. If pipe is too small, undue loss

of volume will occur.

 

 

Installation must include an equipment shutoff valve, union and

plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge

hook up. NPT tap must be upstream from fireplace (see Figure 31).

IMPORTANT: Install main gas valve (equipment shutoff valve)

in an accessible location. The main gas valve is for turning on or

shutting off the gas to the appliance.

 

Check your building codes for any special requirements for locating

equipment shutoff valve to fireplaces.

 

Apply pipe joint sealant lightly to male NPT threads. This will

prevent excess sealant from going into pipe. Excess sealant in pipe

could result in clogged fireplace valves.

 

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

 

We recommend that you install a sediment trap/drip leg in supply

line as shown in Figure 31. Locate sediment trap/drip leg where it

is within reach for cleaning. Install in piping system between fuel

supply and fireplace. Locate sediment trap/drip leg where trapped

matter is not likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into fireplace gas con-

trols. If sediment trap/drip leg is not installed or is installed wrong,

fireplace may not run properly.

 

 

 

CSA Design-Certified

 

Equipment Shutoff Valve

 

with 1/8" NPT Tap*

 

 

Natural - From

 

 

Gas Meter (5.5"

 

 

W.C. to 10.5"

Approved Flexible

 

W.C. Pressure)

Gas Line

 

Propane/LP

 

 

From External

 

 

Regulator (11"

 

 

W.C. to 14" W.C.

3" Minimum

Pressure)

 

 

Cap

Pipe Nipple Tee Joint

Figure 31 - Gas Connection

Sediment Trap/Drip Leg

 

 

*The CSAdesign-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer.

www.desatech.com

116647-01A

Image 18
Contents For Your Safety For Your Safety What to do if YOU Smell GASSave this manual for future reference Table of Contents Safety InformationSafety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationAny wall. This will cause a fire hazard Vent Pipe ConnectionsConnecting Vent Cap with Horizontal Vent Pipe Horizontal Termination Configurations Venting InstallationInstructions Vertical Horizontal HVenting with Two 90 Elbows Horizontal H Vertical Min Max 12 max 18 max 20 max20 max Max Installation for Vertical Termination Horizontal H 1 +Vertical Horizontal H Min Max 12 max 18 max 20 max Flat Ceiling Installation Vertical Termination ConfigurationsVertical V Horizontal H1 + Horizontal H2 Min Max 20 max Vertical V Horizontal H Min Max 12 max 18 max 20 max Venting with One 90 ElbowVertical Horizontal H Min Max 20 max Vertical VentingHigh Altitude Installation Desa 5/8 Pipe & Vent KitsNumber Description Fireplace Installation Check GAS Type Installing Optional Blower AccessoryFireplace Installation Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door Removing Glass DoorInstalling Optional Brick Liner Model BL32D Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Optional Remote Control Wiring DiagramWall Switch Installation For Your Safety Read Before LightingTo Turn OFF GAS To Appliance Operating Optional Blower AccessoryLighting Optional RemoteInspecting Burners Cleaning MaintenancePilot Assembly Glass DoorPilot and Burners LogsVenting System Troubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at TopTechnical Service Replacement PartsSpecifications Service Hints Parts Under WarrantyIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListBurner Assembly Models 109KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Warranty Information Keep this Warranty