Desa (V)T32EN-A Series, (V)T32EP-A Series Replacement Parts, Specifications Service Hints

Page 29

REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE

29

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESAʼs Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

SPECIFICATIONS

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Customer Service Depart- ment at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESAʼs technical service web site at www.desatech.com.

 

(V)T32EN(R)-A

(V)T32EP(R)-A

 

 

 

Btu

12,000/18,000 Btu/hr

11,000/17,000 Btu/hr

Gas Type

Natural

Propane/LP

Ignition

Piezo

Piezo

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

5.5" w.c.

11.0" w.c.

Dimension (H x W x D) Fireplace

 

 

(Actual size of firebox.

32 1/4" x 34 1/2" x 16 5/8"

32 1/4" x 34 1/2" x 16 5/8"

Measurements do not include

819 x 876 x 422 mm

819 x 876 x 422 mm

nailing flanges or standoffs).

 

 

Carton

33 1/2" x 37 1/2" x 17 1/2"

33 1/2" x 37 1/2" x 17 1/2"

 

851 x 953 x 445 mm

851 x 953 x 445 mm

Weight, lbs/kg*

 

 

Fireplace

80 lbs/36 kg

80 lbs/36 kg

Shipping

83 lbs/38 kg

83 lbs/38 kg

*For refractory lined models add 45 pounds.

116647-01A

www.desatech.com

Image 29
Contents Save this manual for future reference For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Any wall. This will cause a fire hazardConnecting Vent Cap with Horizontal Vent Pipe Instructions Venting InstallationHorizontal Termination Configurations Vertical Horizontal H20 max Max Venting with Two 90 ElbowsHorizontal H Vertical Min Max 12 max 18 max 20 max Vertical Horizontal H Min Max 12 max 18 max 20 max Installation for Vertical TerminationHorizontal H 1 + Vertical V Horizontal H1 + Horizontal H2 Min Max 20 max Flat Ceiling InstallationVertical Termination Configurations Vertical Horizontal H Min Max 20 max Venting with One 90 ElbowVertical V Horizontal H Min Max 12 max 18 max 20 max Vertical VentingNumber Description High Altitude InstallationDesa 5/8 Pipe & Vent Kits Installing Optional Blower Accessory Fireplace Installation Check GAS TypeBlower Wiring Diagram Fireplace InstallationModel BKT Installation Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Cleaning Glass Door Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Model BL32DInstalling Logs No and No Wall Switch Installation Wiring DiagramOptional Remote Control For Your Safety Read Before LightingLighting Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance Optional RemotePilot Assembly Cleaning MaintenanceInspecting Burners Glass DoorVenting System Pilot and BurnersLogs Observed Problem Possible Cause Remedy TroubleshootingTop Gas leak. See Warning statement atSpecifications Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts List109 Burner Assembly ModelsKEY Part Number Description QTY Accessories Owners Registration Form Postage Required 116647-01A Keep this Warranty Warranty Information