VENTING INSTALLATION
INSTRUCTIONS
Continued
Vertical Termination Configurations
Figures 28 through 31 show four different configurations for verti- cal termination.
| Venting with Three 90° Elbows | ||
Note: Install | Vertical (V) | Horizontal (H1) + | |
| Horizontal (H2) | ||
restrictor ring |
| ||
into inner pipe | 8' min. | 5' max. | |
section prior to | 10' min. | 8' max. | |
attaching vent | 12' min. | 11' max. | |
termination cap. | |||
14' min. | 14' max. | ||
| |||
| 16' min. | 17' max. | |
| 18' min. | 20' max. | |
| 40' max. | 20' max. |
90° Elbow
VENTING INSTALLATION INSTRUCTIONS | 15 |
Installation for Vertical Termination (Cont.) |
Note: Install restrictor ring into inner pipe section prior to attaching vent termination cap.
| Venting with Two 90° Elbows | ||
| Vertical (V) | Horizontal H | |
90° Elbow | 8' min. | 6' max. | |
9' min. | 8' max. | ||
| |||
| 10' min. | 10' max. | |
| 12' min. | 14' max. | |
| 14' min. | 18' max. | |
| 40' max. | 20' max. |
Figure 28 - Vertical Venting Configuration using Three 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)
Figure 29 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)
Note: Install restrictor ring into inner pipe section prior to attaching vent termination cap.
90° Elbow
Venting with Two 90° Elbows
Vertical (V1) | Horizontal (H) |
8' min. | 9' max. |
9' min. | 11' max. |
10' min. | 13' max. |
12' min. | 17' max. |
14' min. | 20' max. |
Note: Vertical (V1) + Vertical (V2) = 40' max.
Max. Horizontal Above 14' Vertical = 20'
Figure 30 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)
www.desatech.com |