Desa P), (V) CD36T(N, (V) CD36R(N installation manual Gas leak. See Warning statement at

Page 35

TROUBLESHOOTING

35

Electronic Ignition System (Cont.)

TROUBLESHOOTING

Electronic Ignition System (Continued)

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Fireplace produces a clicking/ticking noise

1.

Metal expanding while heating or con-

1.

This is common with most fireplaces. If

just after burner is lit or shut off

 

tracting while cooling

 

noise is excessive, contact qualified ser-

 

 

 

 

vice person

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 23)

 

2.

Control valve defective

2.

Replace gas conrol valve

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set that the flame does

 

 

and burner

 

not excessively impinge on log surfaces

 

2.

Gas leak. See Warning statement at

2.

Inspect the opening at the base of the

 

 

top of page

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

6.

Replace faulty components

 

 

 

7.

Check for proper installation or remove

 

2.

Air holes at burner inlet blocked

 

debris or blockage.

 

 

 

 

 

 

3.

Burner flame holes blocked

1.

Properly locate logs (see Installing Logs,

 

4.

Improper venting or excessive blockage

 

Lava Rock, and Glowing Embers, page 25)

 

 

 

2.

Clean out air holes at burner inlets, Pe-

 

 

 

 

riodically repeat as needed

 

5.

Excessive amounts of embers and pan

3.

Remove blockage or replace burner

 

 

material

4.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restrictions or blackage

 

 

 

5.

Clear excess embers from around the rear

 

 

 

 

main ports. Use a minimum of one layer

 

 

 

 

of smaller ember peices to acheive the

 

 

 

 

best glowing effect over the visible areas

116035-01B

www.desatech.com

Image 35
Contents Dedicated Rear and TOP Vent Fireplaces OWNER’S Operation Installation ManualFor Your Safety For Your Safety What to do if YOU Smell GASSafety Information Local Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesFraming and Finishing PRE-INSTALATION PreparationClearances Mantel Clearances Unit DimensionsMinimum Clearances for Termination Cap Location of Termination CAPInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Siding Standoff With Vinyl Siding Horizontal Termination ConfigurationGround Floor Installation TOP Vent Venting with Three 90 Elbows Venting with Two 90 ElbowsFlat Ceiling Installation Vertical Termination Configurations Number Description Parts Lists for Venting Kits and ComponentsVertical Venting Electrical Supply Connection Optional Blower InstallationModel BK Installation Model BKT Installation Wiring Diagram Decal Front of BlowerMillivolt Wiring Scheme Wiring DiagramsReceiver Volt Alkaline Battery Terminal Wires Battery Clip Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverCheck GAS Type High Altitude InstallationInstalling GAS Piping to Fireplace GAS Supply and PipingPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Natural FromEquipmentOpen Shutoff Valve Closed Checking GAS ConnectionsTest Pressures In Excess of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaHearth Access and Assembly Operating Fireplace Installing Logs and Glowing EmbersFor Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceOperating Fireplace Electronic Ignition System Optional Wireless Remote OperationThermostat Series Model Ghrctb ON/OFF Series Model GhrcbInspecting Burners Logs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy Troubleshooting Inlet gas pressure is too low Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown KEY VCD36RN VCD36TN VCD36RP VCD36TP Description QTY Parts ListIllustrated Parts Breakdown KEY VCD36RN VCD36RP VCD36TN VCD36TP Description QTY 29 2 KEY VCD36RNE VCD36RPE VCD36TNE VCD36TPE Description QTY Accessories 116035-01B OWNER’S Registration Form Industrial Drive Box Bowling Green, KY Page Industrial Drive P.O. Box Model Serial No Date Purchased