Desa (V) CD36T(N, (V) CD36R(N, P) installation manual Optional Wireless Remote Operation

Page 27

OPERATING FIREPLACE - Electronic Ignition System

27

For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Optional Wireless Remote Operation

OPERATING FIREPLACE

Electronic Ignition System

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty, damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floorbecause some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s Phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of a new heater, the burning of residues from the manufacturing process of the firebox and logs will produce a paper-burning smell and orange flames. Open a window for the first few hours of operation to adequately vent this smell.

Equipment Shutoff Valve

Adjustment

Screw

OFF

 

ON

Figure 59 - Turning Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Open lower louver panel.

4.Turn equipment shutoff valve clockwise to OFF. Do not force.

5.Close lower louver panel.

1.

STOP! Read the safety information above.

 

2.

Turn off all electrical power to the fireplace.

 

3.

Turn wall switch to the OFF position.

 

4.

Open lower louver panel.

 

5.

Turn equipment shutoff valve clockwise

to the OFF

 

position (see Figure ##). Do not force.

 

6.

Wait five (5) minutes to clear out any gas. Then smell for.

 

gas, including near the floor. If you smell gas, STOP! Fol-

 

low “B” in the safety information above. If you don’t smell

Pilot Burner

Figure 60 - Pilot

Sensor Rod

Ignitor

 

gas go to the next step.

 

7.

Turn equipment shutoff valve counterclockwise

to.

 

the ON position. Do not force.

 

8.

Close lower louver panel.

 

9.

Turn on all electric power to the fireplace.

 

10.

Turn the wall switch to the ON position.

 

11.

Visually locate the pilot. The ignitor should begin to spark and

 

the main burner should ignite once flame appears at pilot.

 

 

If lighting the appliance for the first time each season, it

 

 

may take several attemps before the supply gas can reach

 

 

the pilot and main burner.

 

 

If the appliance will not stay lit after several attempts,

 

 

follow the instructions To Turn Off Gas To Appliance, be-

 

 

low, and call your service technician or gas supplier.

 

OPTIONAL WIRELESS

REMOTE OPERATION

Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 43). Follow installation instructions included with the remote control.

1.Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote unit.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press the ON/OFF button to turn the burner on and off.

116035-01B

www.desatech.com

Image 27
Contents Dedicated Rear and TOP Vent Fireplaces OWNER’S Operation Installation ManualFor Your Safety For Your Safety What to do if YOU Smell GASSafety Information Local Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesPRE-INSTALATION Preparation ClearancesFraming and Finishing Mantel Clearances Unit DimensionsMinimum Clearances for Termination Cap Location of Termination CAPInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Siding Standoff With Vinyl Siding Horizontal Termination ConfigurationGround Floor Installation TOP Vent Venting with Three 90 Elbows Venting with Two 90 ElbowsFlat Ceiling Installation Vertical Termination Configurations Parts Lists for Venting Kits and Components Vertical VentingNumber Description Optional Blower Installation Model BK InstallationElectrical Supply Connection Model BKT Installation Wiring Diagram Decal Front of BlowerMillivolt Wiring Scheme Wiring DiagramsReceiver Volt Alkaline Battery Terminal Wires Battery Clip Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverCheck GAS Type High Altitude InstallationInstalling GAS Piping to Fireplace GAS Supply and PipingPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Natural FromEquipmentOpen Shutoff Valve Closed Checking GAS ConnectionsTest Pressures In Excess of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaHearth Access and Assembly Installing Logs and Glowing Embers For Your Safety Read Before LightingOperating Fireplace Optional HAND-HELD Remote Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceOperating Fireplace Electronic Ignition System Optional Wireless Remote OperationThermostat Series Model Ghrctb ON/OFF Series Model GhrcbInspecting Burners Logs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingInlet gas pressure is too low Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown KEY VCD36RN VCD36TN VCD36RP VCD36TP Description QTY Parts ListIllustrated Parts Breakdown KEY VCD36RN VCD36RP VCD36TN VCD36TP Description QTY 29 2 KEY VCD36RNE VCD36RPE VCD36TNE VCD36TPE Description QTY Accessories 116035-01B OWNER’S Registration Form Industrial Drive Box Bowling Green, KY Page Industrial Drive P.O. Box Model Serial No Date Purchased