CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passages of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive househol cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door, on page 23 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manufac- turer should be used when replacing broken or dam- aged glass door panel (see Replacement Parts, page ##). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replaceing Glass Door, page 24). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacumm if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page ## for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, on page 24 for instructions for replaceing glass door.

WARNING: Do not operate fireplace with glass door removed, cracked, or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace

Burner and controls should be cleaned with compressed air to remove dust. dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs and Glowing Embers, page 25, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 36.

Replace ember material periodically as needed. See Replace- ment Parts on page 36.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidlines:

1.Check areas of venting system that are exposed to the weather corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight ito vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been distributed and loosened. Check mechanical supports such as wall straps for rigidity.

www.desatech.com

116035-01B

Image 30
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Dedicated Rear and TOP Vent FireplacesSafety Information Safety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationPRE-INSTALATION Preparation ClearancesFraming and Finishing Unit Dimensions Mantel ClearancesLocation of Termination CAP Minimum Clearances for Termination CapVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Siding Standoff Horizontal Termination Configuration With Vinyl SidingGround Floor Installation TOP Vent Venting with Two 90 Elbows Venting with Three 90 ElbowsFlat Ceiling Installation Vertical Termination Configurations Parts Lists for Venting Kits and Components Vertical VentingNumber Description Optional Blower Installation Model BK InstallationElectrical Supply Connection Wiring Diagram Decal Front of Blower Model BKT InstallationWiring Diagrams Millivolt Wiring SchemeInstalling Remote Receiver Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Receiver Volt Alkaline Battery Terminal Wires Battery ClipGAS Supply and Piping High Altitude InstallationInstalling GAS Piping to Fireplace Check GAS TypeNatural From Connecting Fireplace to GAS SupplyInstallation Items Needed Propane/LPTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess of 1/2 Psig 3.5 kPa EquipmentOpen Shutoff Valve ClosedHearth Access and Assembly Installing Logs and Glowing Embers For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Optional HAND-HELD Remote OperationOptional Wireless Remote Operation Operating Fireplace Electronic Ignition SystemON/OFF Series Model Ghrcb Thermostat Series Model GhrctbInspecting Burners Pilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyInlet gas pressure is too low Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Technical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Parts List KEY VCD36RN VCD36TN VCD36RP VCD36TP Description QTYIllustrated Parts Breakdown KEY VCD36RN VCD36RP VCD36TN VCD36TP Description QTY 29 2 KEY VCD36RNE VCD36RPE VCD36TNE VCD36TPE Description QTY Accessories 116035-01B OWNER’S Registration Form Industrial Drive Box Bowling Green, KY Page Model Serial No Date Purchased Industrial Drive P.O. Box