Desa P) Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 26

26

OPERATING FIREPLACE - Manual Ignition System

For Your Safety Read Before Lighting (cont.)

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

Operating Hand-Held Remote Operation

OPERATING FIREPLACE

Manual Ignition System (Continued)

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Turn off all electric power to the fireplace.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Wait five (5) minutes to clear out any gas. Then smell for. gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas go to the next step.

6.The pilot is located by the main burner and should not re- quire accessing for lighting.

7.Turn gas control knob counterclockwise to “PILOT”.

8.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas suppier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service techni- cian or gas supplier.

9.Turn on all electric power to fireplace.

10.Turn gas control knob counterclockwise to “ON”.

11.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

12.Close lower louver panel.

Gas Control

 

Variable Control Knob

 

 

 

 

Knob

 

 

Piezo

 

 

 

ILOT

N

IH

Ignitor

P

O

 

 

F

 

 

 

F

 

 

 

O

 

 

 

 

 

LO

 

Figure 58 - Control Valve Millivolt

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set the wall switch to the OFFposition or the GHRC selector switch (when equipped) to prevent draining the battery.

3.Turn off all electric power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Berners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set the wall switch to the OFFposition or the GHRC selector switch (when equipped) to prevent draining the battery.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replaceing Glass Door, page 24).

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door, page 24).

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 43). Follow instructions included with the remote control.

NOTICE:You must light the pilot before using the hand- held remote control unit. See Lighting Instructions.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 61, page 28). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

www.desatech.com

116035-01B

Image 26
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Dedicated Rear and TOP Vent FireplacesSafety Information Safety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationFraming and Finishing PRE-INSTALATION PreparationClearances Unit Dimensions Mantel ClearancesLocation of Termination CAP Minimum Clearances for Termination CapVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Siding Standoff Horizontal Termination Configuration With Vinyl SidingGround Floor Installation TOP Vent Venting with Two 90 Elbows Venting with Three 90 ElbowsFlat Ceiling Installation Vertical Termination Configurations Number Description Parts Lists for Venting Kits and ComponentsVertical Venting Electrical Supply Connection Optional Blower InstallationModel BK Installation Wiring Diagram Decal Front of Blower Model BKT InstallationWiring Diagrams Millivolt Wiring SchemeInstalling Remote Receiver Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Receiver Volt Alkaline Battery Terminal Wires Battery ClipGAS Supply and Piping High Altitude InstallationInstalling GAS Piping to Fireplace Check GAS TypeNatural From Connecting Fireplace to GAS SupplyInstallation Items Needed Propane/LPTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess of 1/2 Psig 3.5 kPa EquipmentOpen Shutoff Valve ClosedHearth Access and Assembly Operating Fireplace Installing Logs and Glowing EmbersFor Your Safety Read Before Lighting To Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Optional HAND-HELD Remote OperationOptional Wireless Remote Operation Operating Fireplace Electronic Ignition SystemON/OFF Series Model Ghrcb Thermostat Series Model GhrctbInspecting Burners Pilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyInlet gas pressure is too low Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Technical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Parts List KEY VCD36RN VCD36TN VCD36RP VCD36TP Description QTYIllustrated Parts Breakdown KEY VCD36RN VCD36RP VCD36TN VCD36TP Description QTY 29 2 KEY VCD36RNE VCD36RPE VCD36TNE VCD36TPE Description QTY Accessories 116035-01B OWNER’S Registration Form Industrial Drive Box Bowling Green, KY Page Model Serial No Date Purchased Industrial Drive P.O. Box