Desa T32p-a SERIES, CGDV32pR Installation for vertical termination, Flat Ceiling Installation

Page 14

Venting Installation

instructions

Continued

installation for vertical termination

Note: Vertical restrictor must be installed in all vertical installations.

1.Determine the route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct the venting system, consider an offset (see Figure 19) to avoid cut- ting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations.

2.Set the fireplace in desired location. Drop a plumb line down from the ceiling to the posi- tion of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point.

Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.

Roof

Flashing

Wall Strap

45° Elbow

Ceiling

Firestop

Figure 19 - Offset with Wall Strap and 45°

Elbows

Flat Ceiling Installation

1. Cut a 10 3/4" square hole in the ceiling using the locating hole as a center point. The open- ing should be framed to 10 3/4" x 10 3/4" inside dimensions, as shown in Figure 9 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceiling or an attic, nail firestop from the top side. This prevents loose insula- tion from falling into the required clearance space. If the area above the ceiling is a living space, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 20).

2. Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. Be sure all pipe and elbow connections are fully twist-locked (see Figure 8, page 9).

3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 10 3/4" x 10 3/4" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combustible materials. Frame the opening as shown in Figure 9, page 9.

4. Connect a section of pipe and extend up through the hole.

Note: If an offset is needed to avoid obstruc- tions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Fig- ure 19). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.

5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material over- laps the top edge of the flashing as shown in Figure 19. There must be a 1" clearance from the vent pipe to combustible materials.

If area above is an

If area above is a

attic or insulated

living space, install

area, install firestop

firestop below framed

above framed hole.

hole.

Figure 20 - Installing Firestop

14

www.desatech.com

116646-01D

Image 14
Contents PROPANE/LP GAS Tudor Models VT32P-A Series Natural GAS Tudor Models VT32N-A SeriesCGDV32NR CGDV32PRTable of Contents Safety InformationHigh traffic areas Local Codes Product FeaturesProduct Identification Clearances Pre-Installation PreparationLocation and space requirements Proper clearances must be maintainedFraming Clearances for Corner Installation Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Female Locking Lugs Male SlotsInstalling Siding Standoff Combustible Exterior Vertical V Horizontal H Venting InstallationSquare Termination Round Termination Kit HTK ShownCorner Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsConnect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Venting with One 90 Elbow Vertical V Horizontal HVertical Venting High Altitude InstallationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessory Check GAS TypePlug in blower power cord Model BKT InstallationPlug in blower power cord to duplex outlet Blower Wiring DiagramInstalling Gas Piping to Fireplace Location Installation Items NeededWrong, fireplace may not run properly Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPa Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Removing Louver Panels Installing Remote ReceiverRemoving/Replacing Glass Door Cleaning Glass Door Installing Optional Brick liner Model BL32DReplace screen/rod assembly by reversing step Removing Glass DoorInstalling logs, lava rock and glowing embers Close top and bottom louversFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Optional Hand-HeldThermostat Series On/Off SeriesInspecting Burners Operating optional blower accessoryPilot Assembly Operating optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Troubleshooting Observed Problem Possible Cause RemedyDelayed ignition burner Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isImproper vent cap installa MixerGas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty