Desa T32N-a SERIES, CGDV32pR, T32p-a SERIES installation manual Accessories

Page 37

Accessories

NOTICE: All accessories may not be available for all fireplace models.

Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA’s Sales Department at 1-866-672-6040. for information. You can also write to the address listed on the back page of this manual.

Brick Liner (Not Shown)

BL32D - Refractory Brick Liner Kit

This brick liner adds a touch of style to your direct- vent fireplace. Complete installation instructions included in this manual.

Thermostatically- controlled blower kit - BKT

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instructions included in this manual.

Flexible gas Line connector GA5081 (Not Shown)

For all models.

Propane/natural gas conversion kit (Not Shown)

PCD-32T- Propane/LP Gas Conversion Kit NCD-32T- Natural Gas Conversion Kit

Face/Louver Panel kit (Not Shown)

RLD32 - Rolled Louver Panels, Black

Louver trim kit (Rolled Louvers Only) (Not Shown)

LT32B - Brushed Brass

LT32P - Platinum

LT32PB - Polished Brass

Deflection hoods (Not Shown)

HD32 - Hood - Black (2" Brow)

Perimeter Trim kit (Not Shown)

PT32 - Black

PT32B - Brushed Brass

PT32P - Platinum

PT32PB - Polished Brass

Manual blower Kit - BK

Manual variable control blower accessory provides better heat distribution. Complete installation and operation instructions included in this manual.

Receiver and Hand-Held

Thermostat Remote Control

Kit - HRC200 and HRC201

For all Remote-Ready Models. Allows the fire- place to be operated in a manually or thermostati- cally-controlled mode. You can adjust your heat settings and turn the fireplace on or off without leaving the comfort of your easy chair. A wall- mount docking station is included.

Receiver and Hand-Held on/off Remote Control Kit - HRC100 AND HRC101

For all Remote-Ready Models. Allows the fireplace to be turned on and off conveniently. A wall-mount docking station is included.

Wall mounted thermostat control kit - gwmt1 (Not Shown)

Allows easy wall access for thermostatic operation of your fireplace.

Wall mounted on/off switch gwmS2 (Not Shown)

Allows burner system to be turned on and off with a wall switch.

116646-01D

www.desatech.com

37

Image 37
Contents CGDV32NR Natural GAS Tudor Models VT32N-A SeriesPROPANE/LP GAS Tudor Models VT32P-A Series CGDV32PRSafety Information Table of ContentsHigh traffic areas Product Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Proper clearances must be maintainedFraming Clearances for Corner Installation Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsFemale Locking Lugs Male Slots Installation PlanningInstalling Siding Standoff Combustible Exterior Square Termination Venting InstallationVertical V Horizontal H Round Termination Kit HTK ShownCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Venting with One 90 Elbow Vertical V Horizontal H Twist-lock the vent cap onto the last section of vent pipeParts list for venting kits and components High Altitude InstallationVertical Venting Desa 5/8 Pipe & Vent Kits Number DescriptionInstalling optional blower accessory Fireplace InstallationModel BK Installation Check GAS TypeModel BKT Installation Plug in blower power cordBlower Wiring Diagram Plug in blower power cord to duplex outletInstallation Items Needed Installing Gas Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyWrong, fireplace may not run properly Pressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Test Pressures Equal To or Less Than Psig 3.5 kPa Removing/Replacing Glass Door Installing Remote ReceiverRemoving Louver Panels Replace screen/rod assembly by reversing step Installing Optional Brick liner Model BL32DCleaning Glass Door Removing Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersOperating Fireplace For Your Safety Read Before LightingLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldOn/Off Series Thermostat SeriesPilot Assembly Operating optional blower accessoryInspecting Burners Operating optional GWMT1 Wall Mounted ThermostatBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused by Replace pilot assemblyDelayed ignition burner After pilot lights, keep gas Improper vent cap installa When burner is lit HI position when burner is Cold Minute Air in gas line Operate burner until air is MixerStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace