Desa T32p-a SERIES, CGDV32pR Operating Fireplace, For Your Safety Read Before Lighting

Page 26

Fireplace

Installation

Continued

6.Place log #6 (left log) onto two pins on the left side of back and front log. See Figure 49.

7.Place lava rock along sides and front of firebox bottom in areas that are visible only. It is not necessary to use all of the lava rock provided.

8.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 50). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

9.Close glass door, lock door latches, replace screen and close louvers (see steps 5 and 7 of

Removing Glass Door, page 24).

4

Figure 48 - Installing Log No. 4

6

5

Figure 49 - Installing Logs No. 5 and No. 6

Ember Material

Figure 50 - Placing Ember Material on

Burner

Operating Fireplace

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician.

Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

26

www.desatech.com

116646-01D

Image 26
Contents PROPANE/LP GAS Tudor Models VT32P-A Series Natural GAS Tudor Models VT32N-A SeriesCGDV32NR CGDV32PRTable of Contents Safety InformationHigh traffic areas Local Codes Product FeaturesProduct Identification Clearances Pre-Installation PreparationLocation and space requirements Proper clearances must be maintainedFraming Clearances for Corner Installation Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Female Locking Lugs Male SlotsInstalling Siding Standoff Combustible Exterior Vertical V Horizontal H Venting InstallationSquare Termination Round Termination Kit HTK ShownCorner Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsConnect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Venting with One 90 Elbow Vertical V Horizontal HVertical Venting High Altitude InstallationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessory Check GAS TypePlug in blower power cord Model BKT InstallationPlug in blower power cord to duplex outlet Blower Wiring DiagramInstalling Gas Piping to Fireplace Location Installation Items NeededWrong, fireplace may not run properly Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPa Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Removing Louver Panels Installing Remote Receiver Removing/Replacing Glass Door Cleaning Glass Door Installing Optional Brick liner Model BL32DReplace screen/rod assembly by reversing step Removing Glass DoorInstalling logs, lava rock and glowing embers Close top and bottom louversFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Optional Hand-HeldThermostat Series On/Off SeriesInspecting Burners Operating optional blower accessoryPilot Assembly Operating optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Troubleshooting Observed Problem Possible Cause RemedyDelayed ignition burner Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isImproper vent cap installa MixerGas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty