9.Follow instructions below to install logs, lava rock and ember material.

10.Close glass door, lock latches on top and bottom of door and replace screen (see steps 5 and 6 of

Removing Glass Door, page 24).

11.Close top and bottom louvers.

Left Side

Brick Panel

Figure 44 - Installing Side Brick Panels

Installing logs, lava rock and glowing embers

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

Open louvers, remove screen, unlock door latches and open glass door. See steps 1 and 2 of Remov- ing Glass Door, page 24. Install logs according to instructions for fireplace model numbers.

1.Place log #1 (rear log) on top of grate. Make sure the notches in the bottom of the log fit over the grate (see Figure 45).

2.Rest log #2 (large front log) on the pins on the front part of the grate (see Figure 46).

3.Place log #3 (crossover log) onto the rear and front logs. Make sure it is seated properly on the smooth surface on the front log and on the pin on the back log as shown in Figure 47.

4.Place log #4 (right log) on the pin on the right side of front log as shown in Figure 48, page 26.

5.Place log #5 (base log) onto the front left part of the grate making sure the notches fit over the prongs of the grate). See Figure 49, page 26.

1

Figure 45 - Installing Log No. 1

2

Figure 46 - Installing Log No. 2

3

Figure 47 - Installing Log No. 3

116646-01D

www.desatech.com

25

Image 25
Contents CGDV32NR Natural GAS Tudor Models VT32N-A SeriesPROPANE/LP GAS Tudor Models VT32P-A Series CGDV32PRSafety Information Table of ContentsHigh traffic areas Product Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Proper clearances must be maintainedFraming Clearances for Corner Installation Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsFemale Locking Lugs Male Slots Installation PlanningInstalling Siding Standoff Combustible Exterior Square Termination Venting InstallationVertical V Horizontal H Round Termination Kit HTK ShownCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Venting with One 90 Elbow Vertical V Horizontal H Twist-lock the vent cap onto the last section of vent pipeParts list for venting kits and components High Altitude InstallationVertical Venting Desa 5/8 Pipe & Vent Kits Number DescriptionInstalling optional blower accessory Fireplace InstallationModel BK Installation Check GAS TypeModel BKT Installation Plug in blower power cordBlower Wiring Diagram Plug in blower power cord to duplex outletInstallation Items Needed Installing Gas Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyWrong, fireplace may not run properly Pressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Test Pressures Equal To or Less Than Psig 3.5 kPa Removing/Replacing Glass Door Installing Remote ReceiverRemoving Louver Panels Replace screen/rod assembly by reversing step Installing Optional Brick liner Model BL32DCleaning Glass Door Removing Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersOperating Fireplace For Your Safety Read Before LightingLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldOn/Off Series Thermostat SeriesPilot Assembly Operating optional blower accessoryInspecting Burners Operating optional GWMT1 Wall Mounted ThermostatBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused by Replace pilot assemblyDelayed ignition burner After pilot lights, keep gasImproper vent cap installa When burner is lit HI position when burner isCold Minute Air in gas line Operate burner until air is MixerStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace