Desa T32p-a SERIES, CGDV32pR Removing/Replacing Glass Door, Installing Remote Receiver

Page 23

Fireplace

Installation

Continued

Installing Optional Wireless hand-held REMOTE CONTROL HRC100 and HRC200 Series

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1. Open bottom louver and locate the switch bracket on the left.

2. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 38).

4. Attach the terminal wires to the battery.

5. Connect wires from receiver to TH and TPTH to control valve (see Figure 39).

6. Replace the switch bracket.

Receiver

9-Volt Alkaline Battery

Terminal

Wires

Battery Clip

Figure 38 - Attaching Alkaline Battery to

Receiver

To Optional

Remote

Accessory

Figure 39 - Control Valve Terminals

Installing 9-Volt Alkaline Battery in Hand-

Held Remote Control Unit

1. Remove battery cover on back of remote control unit (see Figure 40).

2. Attach terminal wires to the battery. Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

 

Remote Control Unit

 

Battery Cover

Terminal

 

Wires

 

9-Volt

Battery

Battery

Housing

Figure 40 - Installing Battery in Hand-

Held Remote Control Unit

Removing/Replacing Glass Door

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacementpartinformationsee Replacement Parts, page 36.

CAUTION: Wear gloves and safety glasses while handling or removingbrokenglass.Donotre- moveifglassishot.Keepchildren and pets away from glass.

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before re- moving glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by si- multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 41). Repeat for bottom spring latches and pull the lou- vers outward. To install or replace items removed, simply reverse the procedures above.

Spring Latch

Louver Panel

Figure 41 - Removing Louver Panel

116646-01D

www.desatech.com

23

Image 23
Contents CGDV32PR Natural GAS Tudor Models VT32N-A SeriesCGDV32NR PROPANE/LP GAS Tudor Models VT32P-A SeriesSafety Information Table of ContentsHigh traffic areas Local Codes Product FeaturesProduct Identification Proper clearances must be maintained Pre-Installation PreparationLocation and space requirements ClearancesFraming Clearances for Corner Installation Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsFemale Locking Lugs Male Slots Installation PlanningInstalling Siding Standoff Combustible Exterior Round Termination Kit HTK Shown Venting InstallationSquare Termination Vertical V Horizontal HCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsConnect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Venting with One 90 Elbow Vertical V Horizontal H Twist-lock the vent cap onto the last section of vent pipeDesa 5/8 Pipe & Vent Kits Number Description High Altitude InstallationParts list for venting kits and components Vertical VentingCheck GAS Type Fireplace InstallationInstalling optional blower accessory Model BK InstallationModel BKT Installation Plug in blower power cordBlower Wiring Diagram Plug in blower power cord to duplex outlet Installation Items Needed Installing Gas Piping to Fireplace LocationWrong, fireplace may not run properly Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPa Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Removing Louver Panels Installing Remote ReceiverRemoving/Replacing Glass Door Removing Glass Door Installing Optional Brick liner Model BL32DReplace screen/rod assembly by reversing step Cleaning Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersOperating Fireplace For Your Safety Read Before LightingOptional Hand-Held Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceOn/Off Series Thermostat SeriesOperating optional GWMT1 Wall Mounted Thermostat Operating optional blower accessoryPilot Assembly Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingAfter pilot lights, keep gas Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit Delayed ignition burnerMixer When burner is lit HI position when burner isImproper vent cap installa Cold Minute Air in gas line Operate burner until air isStatement above Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty