Desa CGDV32pR Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 27

OPERATIng fireplace

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information on page 26, column 2.

2.Open lower louver panel.

3.Turn off all electric power to the fire- place.

4.Push in gas control knob slightly and turn

clockwise to OFF.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information on page 26, column 2. If you don't smell gas, go to the next step.

6.The pilot is located by the main burner and should not require accessing for lighting.

7.Turn gas control knob counterclockwise to PILOT (see Figure 51).

8.Push in gas control knob all the way and hold. Immediately light the pilot by repeat- edly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 4 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your service technician or gas supplier.

9.Turn on all electric power to the fireplace.

10.Turn gas control knob counterclockwise to ON.

11.This valve is equipped with a HI/LO fea- ture. Set fireplace input as desired.

12.Close lower louver panel.

Gas Control

 

Variable Control Knob

Knob

 

 

 

 

IL

OT

IH

 

P

F

F

 

 

O

 

 

O

 

 

 

N

 

 

 

LO

Piezo Ignitor

Figure 51 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn

clockwise to OFF.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

1. Turn gas control knob clockwise to the PILOT position.

2. Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 24).

2.Follow steps 1 through 8 under Lighting In- structions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 10 through 12 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door, page 23).

optional Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 37). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 52, page 28). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

116646-01D

www.desatech.com

27

Image 27
Contents CGDV32PR Natural GAS Tudor Models VT32N-A SeriesCGDV32NR PROPANE/LP GAS Tudor Models VT32P-A SeriesSafety Information Table of ContentsHigh traffic areas Product Features Product IdentificationLocal Codes Proper clearances must be maintained Pre-Installation PreparationLocation and space requirements ClearancesFraming Clearances for Corner Installation Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsFemale Locking Lugs Male Slots Installation PlanningInstalling Siding Standoff Combustible Exterior Round Termination Kit HTK Shown Venting InstallationSquare Termination Vertical V Horizontal HCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsInstallation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Venting with One 90 Elbow Vertical V Horizontal H Twist-lock the vent cap onto the last section of vent pipeDesa 5/8 Pipe & Vent Kits Number Description High Altitude InstallationParts list for venting kits and components Vertical VentingCheck GAS Type Fireplace InstallationInstalling optional blower accessory Model BK InstallationModel BKT Installation Plug in blower power cordBlower Wiring Diagram Plug in blower power cord to duplex outletInstallation Items Needed Installing Gas Piping to Fireplace LocationConnecting Fireplace to GAS Supply Checking GAS ConnectionsWrong, fireplace may not run properly Installing optional wall Mount Switch gwmS2 Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Remote Receiver Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass Door Installing Optional Brick liner Model BL32DReplace screen/rod assembly by reversing step Cleaning Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersOperating Fireplace For Your Safety Read Before LightingOptional Hand-Held Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceOn/Off Series Thermostat SeriesOperating optional GWMT1 Wall Mounted Thermostat Operating optional blower accessoryPilot Assembly Inspecting BurnersCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingAfter pilot lights, keep gas Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit Delayed ignition burnerMixer When burner is lit HI position when burner isImproper vent cap installa Cold Minute Air in gas line Operate burner until air isStatement above Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceAccessories Illustrated Parts Breakdown Parts List Illustrated parts breakdown Burner Base Assembly 116646-01D 116646-01D Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace