INSTALLATION
Installing Gas Piping To Fireplace Location (Cont.) Connecting Fireplace Insert To Gas Supply
11
INSTALLATION |
|
Continued |
|
External |
|
Regulator | Propane/LP |
| |
| Supply |
| Tank |
Vent Pointing |
|
Down |
|
Figure 13 - External Regulator with Vent Pointing Down
Installation must include an equipment shutoff valve, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace insert (see Figure 14).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace insert gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CONNECTING FIREPLACE INSERT TO GAS SUPPLY
Installation Items Needed
•5/16" hex socket wrench or
•Phillips screwdriver
•sealant (resistant to propane/LP gas, not provided)
1.Remove fireplace insert screen. Lift fireplace insert screen up and pull out to remove.
2.Remove screws that attach log base assembly to fireplace in- sert (see Figure 15). Carefully lift up log base assembly and remove from fireplace insert (see Figure 15).
Note: If adding the G8010 series brick liner accessory, install it now. Follow instructions in G8010 accessory kit.
CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.
3.Route gas supply line through access opening of fireplace in- sert (see Figure 15).
CSA
| Equipment Shutoff Valve | |
| With 1/8" NPT Tap* | |
Supplied Flexible | Propane/LP | |
Gas Line | ||
From External | ||
| ||
| Regulator (11" | |
| W.C. to 14" W.C. | |
| Pressure) |
| Natural | |
3" Minimum | From Gas Meter | |
(5" W.C. to | ||
| ||
| 10.5" W.C. | |
| Pressure) | |
Cap Pipe | Tee | |
Nipple | Joint |
Sediment Trap
Figure 14 - Gas Connection
*Purchase the optional CSA
Burners
Two Screws
Gas Line
Access
Log Base Assembly
Figure 15 - Removing Log Base Assembly From Fireplace Insert