Desa VI33NR VI33PR installation manual Fireplace Insert Installation Into Masonry Fireplace

Page 13

INSTALLATION

Checking Gas Connections (Cont.)

Fireplace Insert Installation Into Masonry Fireplace

Assembling And Attaching Trim

13

INSTALLATION

Continued

Pressure Testing Fireplace Insert Gas

Connections

1.Open equipment shutoff valve (see Figure 17, page 12).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace insert is in the OFF position.

4.Check all joints from gas meter to equipment shutoff valve for natural gas (see Figure 18, page 12), or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 19, page 12). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace insert (see Operating Fireplace Insert, pages 16 through 18). Check all other internal joints for leaks.

7.Turn off fireplace insert (see To Turn Off Gas to Appliance, page 17).

FIREPLACE INSERT INSTALLATION INTO MASONRY FIREPLACE

Installation of this fireplace insert involves installing fireplace insert into an existing masonry fireplace. If using a mantel above the fireplace, you must follow the clearances shown in Figure 12, page 10. Follow the instructions below to install the fireplace insert in this manner.

 

 

Minimum

 

Insert

Fireplace Opening

Height

25 9/16"

26 1/4"

Front Width

34 5/16"

35"

Depth

16 11/16"

17 1/4"

1.Use dimensions shown in Figure 20 for the masonry fire- place opening.

2.Install and properly ground GA3555, three-prong 120 volt elec- trical outlet, in fireplace insert. Follow instructions included in kit (see Accessories, page 30).

17 1/4"

26 1/4"

35"

Figure 20 - Rough Opening for Installing in Masonry Fireplace

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 10 and 11.

4.Carefully set fireplace insert in front of masonry fireplace with back of insert inside wall opening.

5.Attach flexible gas line to gas supply. See Connecting Fire- place Insert to Gas Supply, pages 11 and 12.

6.Plug electrical cord into electrical outlet installed in step 2.

7.Carefully place fireplace insert into masonry fireplace.

8.Check all gas connections for leaks. See Checking Gas Con- nections, pages 12 and 13.

9.Install trim after final finishing and/or painting of wall (see Figure 22, page 14).

ASSEMBLING AND ATTACHING TRIM

1.Remove three pieces of surround trim from packaging.

2.Locate four #6 screws, two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 21.

4.Slide one end of adjusting plate/shim in slot of top surround trim (see Figure 21).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side surround trim (see Figure 21).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 3 through 6 for other side.

 

 

Set

 

Side

 

Screws

Top Surround

 

Adjusting

Surround

Plate

Trim

Trim

 

 

 

 

 

 

Slot

Slot

 

 

Mitered

 

 

Shim

Edge

 

 

Mitered Edge

 

Figure 21

- Assembling Surround Trim

For morevisit www..com

111285-01B

Image 13
Contents Unvented VENT-FREE GAS Fireplace Insert OWNER’S Operation Installation ManualWhat to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product Features Remote Control AccessoriesProduct Identification UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingCheck GAS Type InstallationVentilation Air From Outdoors Blower Accessory Installing Surround KIT GS38 or GS43Electrical Hookup Installation Clearances Installing HoodMantel Clearances for Insert Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Vent Pointing Down Connecting Fireplace Insert to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Fireplace Insert Installation Into Masonry FireplaceAssembling and Attaching Trim Attaching Trim to Fireplace Surround Installing LogsInstalling 9-Volt Battery Not Included in Receiver Installing 9-VOLT BatteriesOperating Fireplace Insert For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbAuto Thermostatic Mode Manual ModeSafety Features Thermostat Series Model GhrctbPilot Flame Pattern Inspecting BurnersBurner Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Specifications Wiring DiagramsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsService Hints Parts Under WarrantyModels VI33NR and VI33PR Illustrated Parts BreakdownKEY Part Number VI33NR VI33PR Description QTY Parts ListFireplace Insert VI33NR and VI33PR KEY Part Number Description QTY WALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesWALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKOwners Registration Form Tape 111285-01B Warranty Information