Desa VI33NR VI33PR Operating Fireplace Insert, For Your Safety Read Before Lighting

Page 16

16

OPERATING FIREPLACE INSERT

For Your Safety Read Before Lighting Lighting Instructions

OPERATING FIREPLACE INSERT

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this heater with the fireplace insert screen in place. Make sure fireplace insert screen is installed before running fireplace insert.

NOTICE: During initial operation of new fireplace insert, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Set switch to OFF position.

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 17.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

 

 

Ignitor

 

 

 

Button

 

IH

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

F

AUTO

 

N

 

P

F

LO

O

TOL

 

OFF

 

 

I

 

 

 

 

 

 

 

ON

Flame Adjustment

 

Control Knob

Selector Switch

Knob

 

 

 

 

Figure 32 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

Pilot Burner

Ignitor

Pilot Burner

Ignitor

 

Electrode

 

 

 

Electrode

 

 

 

WARNING: Burners will come on automatically within one minute when the remote selector switch is in the ON position after the pilot is lit.

Natural Gas

Figure 33 - Pilot

Propane/LP Gas

For..com

111285-01B

Image 16
Contents Unvented VENT-FREE GAS Fireplace Insert OWNER’S Operation Installation ManualWhat to do if YOU Smell GAS Table of Contents Safety InformationLocal Codes Remote Control Accessories Product FeaturesProduct Identification UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingCheck GAS Type InstallationVentilation Air From Outdoors Blower Accessory Installing Surround KIT GS38 or GS43Electrical Hookup Installing Hood Installation ClearancesMantel Clearances for Insert Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace Insert to GAS Supply Vent Pointing DownPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Insert Gas Connections Fireplace Insert Installation Into Masonry FireplaceAssembling and Attaching Trim Installing Logs Attaching Trim to Fireplace SurroundInstalling 9-VOLT Batteries Installing 9-Volt Battery Not Included in ReceiverOperating Fireplace Insert For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbManual Mode Auto Thermostatic ModeSafety Features Thermostat Series Model GhrctbInspecting Burners Pilot Flame PatternBurner Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Wiring Diagrams SpecificationsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Technical ServiceService Hints Parts Under WarrantyIllustrated Parts Breakdown Models VI33NR and VI33PRParts List KEY Part Number VI33NR VI33PR Description QTYFireplace Insert VI33NR and VI33PR KEY Part Number Description QTY Receiver and HAND-HELD Remote Control KIT Ghrcb Series WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKOwners Registration Form Tape 111285-01B Warranty Information