Desa VI33NR VI33PR Thermostat Series Model Ghrctb, Optional Blower Operation, Manual Mode

Page 18

18

OPERATING FIREPLACE INSERT

Optional Hand-Held Remote Operation (Cont.) Optional Blower Operation

OPERATING FIREPLACE INSERT

Continued

THERMOSTAT SERIES (MODEL GHRCTB)

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 36). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower louver on fireplace insert. Blower switch is located at lower left inside louver door.

Digital Display

Shows

Temperature and

Settings

Turns Burners

On or Off

Decreases Room

Temperature in

AUTO Mode

Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting

Selects Auto

Setting

Increases Room

Temperature in

AUTO Mode

Locks System to Prevent Accidental Ignition

This thermostat-controlled blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate con- stantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace insert may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace insert with blower turned off. However, the blower helps distribute heated air from the fireplace insert.

Figure 36 - Thermostat Hand-Held Remote Control Unit (GHRCTB)

For..com

111285-01B

Image 18
Contents OWNER’S Operation Installation Manual Unvented VENT-FREE GAS Fireplace InsertWhat to do if YOU Smell GAS Table of Contents Safety InformationLocal Codes Product Identification Remote Control AccessoriesProduct Features UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingInstallation Check GAS TypeVentilation Air From Outdoors Installing Surround KIT GS38 or GS43 Blower AccessoryElectrical Hookup Installing Hood Installation ClearancesInstalling GAS Piping to Fireplace Location Mantel Clearances for Insert InstallationInstallation Items Needed Connecting Fireplace Insert to GAS Supply Vent Pointing DownPressure Testing Gas Supply Piping System Checking GAS ConnectionsFireplace Insert Installation Into Masonry Fireplace Pressure Testing Fireplace Insert Gas ConnectionsAssembling and Attaching Trim Installing Logs Attaching Trim to Fireplace SurroundInstalling 9-VOLT Batteries Installing 9-Volt Battery Not Included in ReceiverFor Your Safety Read Before Lighting Operating Fireplace InsertLighting Instructions Optional HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance ON/OFF Series Model GhrcbSafety Features Manual ModeAuto Thermostatic Mode Thermostat Series Model GhrctbBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Wiring Diagrams SpecificationsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Models VI33NR and VI33PRParts List KEY Part Number VI33NR VI33PR Description QTYFireplace Insert VI33NR and VI33PR KEY Part Number Description QTY WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesWALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKOwners Registration Form Tape 111285-01B Warranty Information