OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly

7.Replace gas control

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Equipment shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Fully open equipment shutoff valve

4.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace pilot assembly

7.Replace control valve

For..com

111285-01B

Image 22
Contents Unvented VENT-FREE GAS Fireplace Insert OWNER’S Operation Installation ManualWhat to do if YOU Smell GAS Table of Contents Safety InformationLocal Codes Product Identification Remote Control AccessoriesProduct Features UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingCheck GAS Type InstallationVentilation Air From Outdoors Blower Accessory Installing Surround KIT GS38 or GS43Electrical Hookup Installing Hood Installation ClearancesMantel Clearances for Insert Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace Insert to GAS Supply Vent Pointing DownPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Insert Gas Connections Fireplace Insert Installation Into Masonry FireplaceAssembling and Attaching Trim Installing Logs Attaching Trim to Fireplace SurroundInstalling 9-VOLT Batteries Installing 9-Volt Battery Not Included in ReceiverOperating Fireplace Insert For Your Safety Read Before LightingLighting Instructions Optional HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance ON/OFF Series Model GhrcbSafety Features Manual ModeAuto Thermostatic Mode Thermostat Series Model GhrctbBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Wiring Diagrams SpecificationsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Models VI33NR and VI33PRParts List KEY Part Number VI33NR VI33PR Description QTYFireplace Insert VI33NR and VI33PR KEY Part Number Description QTY WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesWALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKOwners Registration Form Tape 111285-01B Warranty Information