Desa installation manual Vent-Free Propane/Lp Gas Compact Fireplace, Model RFP28TB

Page 1
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

®

Shown with Optional

Hearth Base and Mantel

Model: RFP28TB

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional infor- mation consult a qualified in- staller, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion in this manual.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is permitted after the manufactured (mobile) home is sited)

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Save this manual for future reference.

Image 1
Contents VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALModel RFP28TB WHAT TO DO IF YOU SMELL GAS Do not try to light any applianceSAFETY CONTENTSbefore trying to assemble, operate, or service this heater. Improper INFORMATIONContinued PRODUCT IDENTIFICATION Safety DevicePiezo Ignition System Thermostatic Heat ControlInstalling Log ASSEMBLYASSEMBLING HEATER Removing Front Panel Of HeaterAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass Trim ASSEMBLYAIR FOR This heater shall not be installed in a confined space unlessVENTILATION COMBUSTIONDETERMINING AIR FLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATIONDetermining if You Have a Confined or Unconfined Space Example 51,200If the area in which the heater may be operated is smaller than VENTILATION AIRthat defined as an unconfined space, provide adequate combus tion and ventilation air by one of the methods described in theVentilation Air From Outdoors VENTILATION AIR ContinuedVentilated Outlet Attic Air OutletINSTALLATION ITEMS INSTALLATIONNever install the heater to wall surfaces next to heater. Installing heater next to vinyl orlocate heater where moving vehicle will not hit it If you install the heater in a home garageTHERMOSTAT SENSING BULB heater pilot and burner must be at least 18 inches above floorINSTALLATION OPTIONS INSTALLATIONMounting Bracket Methods For Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket to WallSecuring Hearth Base to Floor Mounting Heater to Optional Hearth Base Assembling Mantel Installing Mantel to HeaterTighten the screws all the way into the holes Use pipe joint sealant that is resistant to liquid petroleum LP gas CONNECTING TO GAS SUPPLYPRESSURE TESTING GAS SUPPLY PIPING SYSTEM CONNECTINGTest all gas piping and connections for leaks after installing or Make sure external regulator has been installed between propaneTest Pressures Equal To or Less Than 1/2 PSIG PRESSURE TESTING HEATER GAS CONNECTIONSOPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS Do not try to adjust heating levels by using the manual shutoff valve TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURETHERMOSTAT CONTROL OPERATION Shutting Off HeaterPILOT FLAME PATTERN INSPECTING BURNERCORRECT FLAME PATTERN AT HIGH POSITION BURNER FLAME PATTERNINCORRECT FLAME PATTERN AT HIGH POSITION qualified service person should service and repair heater Turn off heater and let cool before cleaningNever use a wire, needle, or similar object to clean ODS/pilot. This PROBLEMTROUBLE TROUBLE- SHOOTING Shut off gas supply If you smell gasDo not try to light any appliance If you cannot reach your gas supplier, call the fire departmentREPLACEMENT SERVICEParts Under Warranty Parts Not Under WarrantyPARTS CENTRALS MANUAL SHUTOFF VALVE - GA5010 ACCESSORIESFAN KIT - GA3100A Manual or GA3200TA Thermostat HEARTH BASE - GHB802B or GHB38PRESTIGE MANTEL Unfinished - GMC23UA Finished - GMC22FA GMC24UA STANDARD MANTEL Unfinished - GMU801A,B Finished - GMF800A,BCORNER MANTEL Unfinished - GMC33U Finished - GMC32F 12-2 RFP28TB12-1 PART NUMBER PARTS LIST RFP28TBDESCRIPTION PARTS AVAILABLE - NOT SHOWN101935 101935 LIMITED WARRANTY WARRANTY INFORMATIONCOMFORT GLOW VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE