Desa RFP28TB installation manual Correct Burner Flame Pattern

Page 27

INSPECTING BURNER

Continued

BURNER FLAME PATTERN

Figure 32 shows a correct burner flame pattern. Figure 33 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.

Note: When using the heater the first time, the flame will be yellow for approxi- mately one hour until the log cures.

WARNING

WARNING ICON

G 001

If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

Top of

Flame

About One

Inch Above

Logs

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 32 - Correct Burner Flame Pattern

Yellow

Tipping

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 33 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 33

turn heater off (see To Turn Off Gas to Appliance, page 25).

see Troubleshooting, pages 28 through 31.

101935

27

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Thermostatic Heat Control Safety DeviceProduct Identification Piezo Ignition SystemAssembly Installing LogRemoving Front Panel Of Heater Assembling Heater Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim AssemblyAIR for VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingAppliances in both spaces Ventilation Air From Outdoors Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Marking Screw Locations Installation OptionsMounting Bracket Methods For Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket to WallMounting Heater on Optional Hearth Base Securing Hearth Base to FloorAttaching Heater to Hearth Base Mounting Heater to Optional Hearth BaseAssembling Mantel Installing Mantel to HeaterPre-Drilled Hole Screw Hearth Base Accessory Wood Plug External Regulator with Vent Pointing Down Connecting to GAS SupplyChecking GAS ConnectingTo GAS SupplyChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternTrouble Shooting ODS/PILOT and BurnerCabinet Trouble Cleaning and MainteTROUBLE- Shooting Ing statement at If you smell gasShut off gas supply Do not try to light any applianceHints ServiceReplacement Parts TechnicalFBD Parts CentralsGS601 Black Surround AccessoriesFAN KIT GA3100A Manual or GA3200TA Thermostat Hearth Base GHB802B or GHB38Unfinished GMU801A,B Finished GMF800A,B Unfinished GMC23UA Finished GMC22FAUnfinished GMC33U Finished GMC32F RFP28TB KEY Part Number Description Parts List RFP28TB101935 101935 Keep this Warranty Warranty Information