SEAR STATION® TROUBLESHOOTING
PROBLEM | CHECK | SOLUTION | |
|
|
| |
Burners burn with a yellow or | Inspect Spider/Insect Screens for possible obstructions.. (Blockage | Clean Spider/Insect Screens.. | |
orange flame, in conjunction with | of holes..) | (See “ANNUAL MAINTENANCE” section) | |
the smell of gas (This is normal for |
|
| |
Did you ignite the two adjacent main burners? (See “SEAR | Verify adjacent main burner ignition by visual inspection of a flame. | ||
the burner lighting tube). | |||
STATION® IGNITION & USAGE” instructions for safe lighting |
| ||
Sear Station® burner does not light. | m WARNING: If ignition does not occur in 5 | ||
procedure) | |||
|
| seconds, turn burner control OFF, wait 5 | |
|
| minutes to let the gas clear before you try | |
|
| again. | |
|
|
| |
| Does Burner light with a match? | If you can light Burner with a match, then check the Crossover® | |
|
| Channel on the sear burner.. | |
|
| (See “MAINTENANCE” for burner removal and cleaning | |
|
| procedure..) | |
|
|
| |
| Does the igniter work (Do you see a spark when you repeatedly | Try manually lighting the burner (refer to “SEAR STATION® | |
| use the snap igniter? | IGNITION & USAGE”).. Call customer service.. | |
|
|
| |
General Symptoms: | The excess flow safety device, which is part of the barbecue to | To reset the excess flow safety device turn all burner control knobs | |
Burner does not light. | cylinder connection, may have activated.. | and the cylinder valve to OFF.. Disconnect the regulator from the | |
| cylinder.. Turn burner control knobs to START/HI.. Wait at least 1 | ||
Burner has a small flickering flame. |
| ||
| minute.. Turn burner control knobs to OFF.. Reconnect the regulator | ||
|
| ||
|
| to the cylinder.. Turn cylinder valve on slowly.. Refer to “MAIN | |
|
| BURNER IGNITION”.. | |
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
ROTISSERIE TROUBLESHOOTING
PROBLEM | CHECK | SOLUTION |
|
|
|
Rotisserie burner does not light. | Did you hold the burner control knob in and hold in for 20 seconds | Try to relight burner by holding burner control knob in and continue |
| until after burner ignited? | holding in until 20 seconds after burner has ignited.. |
|
|
|
| Did you wait to see the entire ceramic surface become alight | When relighting burner by holding burner control knob in, wait to |
| before counting 20 seconds? | see the entire ceramic surface become alight before counting 20 |
|
| seconds? |
|
|
|
| Did you repeatedly use the snap ignition until the burner ignited? | After waiting five minutes for gas to clear, try repeatedly using |
|
| the snap igniter until the burner ignites (refer to “ROTISSERIE |
|
| BURNER IGNITION & USAGE”).. |
|
|
|
| Does the igniter work (Do you see a spark when you repeatedly | Try manually lighting the burner (refer to “ROTISSERIE BURNER |
| use the snap igniter)? | MANUAL IGNITION”).. Call customer service.. |
|
|
|
General Symptoms: | The excess flow safety device, which is part of the barbecue to | To reset the excess flow safety device turn all burner control knobs |
Burner does not light. | cylinder connection, may have activated.. | and the cylinder valve to OFF.. Disconnect the regulator from the |
| cylinder.. Turn burner control knobs to START/HI.. Wait at least 1 | |
has a small flickering flame. |
| |
| minute.. Turn burner control knobs to OFF.. Reconnect the regulator | |
|
| |
|
| to the cylinder.. Turn cylinder valve on slowly.. Refer to “MAIN |
|
| BURNER IGNITION”.. |
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
GRILL OUT™ HANDLE LIGHT TROUBLESHOOTING
PROBLEM | CHECK | SOLUTION | |
|
|
| |
Weber Grill Out™ Handle Light | Are the batteries old? | Replace batteries.. | |
does not light. |
|
| |
Are the batteries installed correctly? | Refer to assembly illustration.. | ||
| |||
|
|
| |
| Is the lid in the up position with the power button ON? | Light will activate when lid is open.. | |
|
|
| |
| Is the Weber Grill Out™ Handle Light activated? | Press the power button.. | |
|
|
| |
| Is the Weber Grill Out™ Handle Light positioned correctly on the | Adjust position (refer to assembly illustration). | |
| handle? |
| |
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
32