Weber E/S 650 manual To Connect the Hose to the Cylinder

Page 15

GAS INSTRUCTIONS

15

TO CONNECT THE HOSE TO THE CYLINDER:

1) Locate hose retention clip (a) on regulator hose. Secure into slot (b) on underside of tank scale.

WARNING: The hose must be secured to the tank scale with the Hose Retention Clip. Failure to do so could cause damage to the hose resulting in a fire or explosion which can cause serious bodily injury or death, and damage to property.

Some LP tanks have differing top collar assembles. (The top collar is the metal protective ring around the valve.) One series of tanks mount with the valve facing front

(a). The other tanks mount with the valve facing away from the fuel scale (b). Weber recommends the use of cylinder manufacturer’s Manchester and Worthington, with a

47.6lb water capacity. Other cylinders may be acceptable for use with the appliance provided they are compatible with the appliance retention means (see illustrations).

The LP cylinder is installed inside the base cabinet, on the tank scale (right side). 2) Open base cabinet doors.

3) Turn the LP cylinder so the opening of the valve is either to the front, side or rear of the Weber® gas barbecue. Lift and hook the cylinder onto the fuel gauge.

4) Lift tank up into position on the tank scale.

5) Loosen the cylinder lock wing nut. Swing the cylinder lock down. Tighten the wing nut.

TO CONNECT THE HOSE TO THE CYLINDER:

6) Remove the plastic dust cover from the valve.

7) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only.

Note: This connection tightens clockwise and will not allow gas to flow unless the connection is tight. The connection requires tightening by hand only.

WARNING: Do not use a wrench to tighten the connection. Using a wrench could damage the regulator coupling and could cause a leak.

You will need: LP cylinder, a soap and water solution and a rag or brush to apply it.

8) Mix soap and water.

9) Turn on the cylinder valve.

10) Check for leaks by wetting the fitting with the soap and water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.

If there is a leak, turn off the gas and tighten the fitting. Turn the gas back on and recheck with the soap and water solution.

If leak does not stop do not use the barbecue. Contact the customer service representative in your area using the contact information on our web site. Log onto www.weber. com®.

11)When leak checking is complete, turn gas supply off at the

source and rinse connections with water.

WWW.WEBER.COM®

Image 15
Contents GAS Grill Liquid Propane GAS Units only 2WARNINGSUSA WARRANTY, GARANTÍA, Garantie650 Parts LIST, Liste DES PIÈCES, Lista DE PiezasExploded View E/S-620 6EXPLODED View List E/S-620 Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision ÉclatéeExploded View E/S-650 Exploded View List E/S-650 ASSEMBLY, ASSEMBLAGE, Ensamblaje ASSEMBLY, ASSEMBLAGE, Ensamblaje 650 AAA Operating Storage AND/OR Nonuse CleaningFor Installation in Canada General InstructionsLeak Check Preparation Connecting the Liquid Propane CylinderGAS Instructions Important LP Cylinder InformationTo Connect the Hose to the Cylinder Check for GAS Leaks Check for GAS Leaks Remove Control PanelCheck 620Check Reinstall Control PanelLiquid Propane Cylinder Requirements Refilling the Liquid Propane CylinderChecking the Fuel Level in Your Tank Safe Handling Tips for Liquid Propane GAS CylindersOperating Instructions Snap Ignition Operation Grilling Tips & Helpful HintsTo Extinguish LightingMain Burner Snap Ignition Main Burner LightingMain Burner Manual Lighting Lighting the Side BurnerSide Burner Lighting To USE the Smoker Using the SmokerSmoker Burner Snap Ignition Lighting the Smoker BurnerManually Lighting the Smoker Burner Using the Rotisserie Important Safeguards OperatingCooking Lighting the Rotisserie Burner Lighting Rotisserie BurnerRotisserie Burner Snap Ignition Operating Instructions Problem Check Cure Rotisserie TroubleshootingHandle Light Troubleshooting Sideburner TroubleshootingSideburner Maintenance TroubleshootingSide Burner Maintenance Replace Main Burners 32MAINTENANCEMain Burner Cleaning Procedure Weber SPIDER/INSECT ScreensBurner Flame Pattern MAINTENANCE33Annual Maintenance Inspection and Cleaning of the SPIDER/INSECT ScreensBarbacoa DE GAS Únicamente Unidades DE GAS Propano Licuado ADVERTENCIAS35Peligro AdvertenciasInstrucciones Generales Cómo Conectar EL Cilindro DE Propano Licuado Instrucciones Sobre EL GASInformación Importante Sobre EL Cilindro DE Propano Licuado Preparativos Para LA Búsqueda DE FugasPara Conectar LA Manguera AL Cilindro Instrucciones Sobre EL GASPrueba DE Fugas DE GAS Compruebe QUE no Haya Fugas DE GAS PeligroRetire EL Panel DE Control Verifique Vuelva a Instalar EL Panel DE Control VerifiqueRequisitos DE LOS Cilindros DE Propano Licuado Cómo Recargar EL Cilindro DE Propano LicuadoCómo Verificar EL Nivel DE Combustible EN SU Tanque Cilindros DE Propano LicuadoInstrucciones DE Operación Funcionamiento DEL Encendido Rápido Consejos Prácticos Para AsarPara APA GAR EncendidoEncendido Rápido DEL Quemador Principal Cómo Encender EL Quemador PrincipalCómo Encender EL Quemador Lateral Encendido Manual DEL Quemador Principal PeligroPara Apagar Cómo Encender EL Quemador Lateral PeligroPara Usar EL Ahumador Encendido Manual DEL Quemador Lateral PeligroEncendido Manual DEL Quemador Lateral Cómo Usar EL AhumadorEncendido Rápido DEL Quemador DEL Ahumador Encendido DEL Quemador DEL Ahumador PeligroEncendido Manual DEL Quemador DEL Ahumador Cócción USO DEL Asador GiratorioMedidas Preventivas Importantes Advertencias OperaciónEncendido DEL Quemador DEL Asador Giratorio Pudiera causar lesiones corporales serias o la muerte Problema Revisar Remedio Resolución DE Problemas CON EL Asador GiratorioResolución DE Problemas DE LA LUZ DEL ASA Resolución DE Problemas CON EL Quemador LateralResolución DE Problemas Mantenimiento DEL Quemador LateralMantenimiento DEL Quemador Lateral Reemplace LOS Quemadores Principales MANTENIMIENTO55Mallas Weber Contra Arañas E Insectos Procedimiento Para LA Limpieza DEL Quemador Principal56MANTENIMIENTO Mantenimiento AnualPatrón DE LA Llama DEL Quemador Barbecue À GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Instructions Generales Raccordement DE LA Bouteille DE Propane Liquide Instructions Relatives AU GAZInformations Importantes Relatives a LA Bouteille DE PL Preparation DE LA Detection DES FuitesPour Raccorder LE Tuyau À LA Bouteille DE GAZ Detection DES Fuites DE GAZ Retrait DU Panneau DE CommandeVérifiez Vérifiez Remise EN Place DU Panneau DE CommandeExigences Relatives À LA Bouteille DE Propane Liquide Rechargement DE LA Bouteille DE Propane LiquideVerification DU Niveau DE Combustible Dans Votre Bouteille Bouteilles DE GAZ Propane Liquide PLInstructions Pour L’UTILISATION Utilisation DU Bouton D’ALLUMAGE Astuces & Conseils Utiles Pour LES GrilladesPour Eteindre AllumageAllumage DU Bruleur DU Fumoir Avec LE Bouton Allumage DU Bruleur PrincipalAllumage Avec L’ALLUMEUR Allumage DU Bruleur LateralNettoyage DU Fumoir Allumage Manuel DU Bruleur LateralUtilisation DU Fumoir Pour Utiliser LE FumoirBouton D’ALLUMAGE DU Bruleur DU Fumoir Allumage DU Bruleur DU FumoirAllumage Manuel DU Bruleur DU Fumoir Precautions DE Securite Importantes Mises EN Garde Utilisation DE LA RotissoireCuisson Allumage DU Bruleur DE LA Rotissoire ’ALLUMER LE Bruleur DE LA RotissoireBouton D’ALLUMAGE DU Bruleur DE LA Rotissoire Instructions Pour L’UTILISATION Guide DE Depannage DU Bruleur Lateral Probleme Verification SolutionGuide DE Depannage DE LA Rotissoire Depannage DE L’ECLAIRAGE DE LA PoigneeMaintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGuide DE Depannage Grilles ANTI-ARAIGNEES/INSECTES Weber Procedure DE Nettoyage DU Bruleur PrincipalRemplacement DES Bruleurs Principaux 78ENTRETIENMaintenance Annuelle ENTRETIEN79Aspect DES Flammes DU Brûleur Page Page WEBER-STEPHEN Products CO By e-mail / Por correo electrónico / Par e-mail Pour les achats effectués aux États-Unis