Teledyne 3110 operating instructions Sensor Installation, Installing a Trace Sensor

Page 20

Installation

Model 3110

 

 

For trace analysis applications, a flowmeter should be installed in the vent line but it should not incorporate any control valves or restrictive devices.

2.3 Sensor Installation

The Model 3110's trace sensor requires that the instrument lines be immediately purged with zero gas after installing the cell.

2.3.1 Installing a Trace Sensor

Prior to installing the trace sensor, make sure the analyzer is ready to purge with zero gas. Connect the vent line to the analyzer then connect the zero gas line to the sample in port. Set the zero gas flow rate between 0.2 and 2.5 SCFH.

Prior to using any bottled gas for calibration or purge, it is good practice to bleed the regulator and sample line to remove any traces of trapped air. See Section 2.4.3 Bleeding the Regulator and Purging the Gas Line.

Once the vent and zero gas lines are attached and the lines bleed, proceed to install the trace sensor as follows:

1.Remove the cell holder cap from the bottom of the instrument.

2.Remove the outer packaging from the sensor.

3.Grab the shorting plug on the top of the sensor and pull it free prior to removing the sensor from its packaging.

4.Remove the packaging and rapidly place the sensor on the top of the cell holder cap with the concentric gold rings facing up.

5.Screw the cell holder cap and sensor into the bottom of the analyzer.

Note: Minimize the time the sensor is exposed to air.

6.Start the purge flow through the analyzer and purge overnight before calibrating the unit.

20 Teledyne Analytical Instruments

Image 20
Contents Model Teledyne Analytical InstrumentsModel Ii Teledyne Analytical InstrumentsSpecific Model Information Portable Trace Oxygen AnalyzerSafety Messages Iv Teledyne Analytical InstrumentsPortable Trace Oxygen Analyzer Table of Contents Index Teledyne Analytical Instruments Maintenance & TroubleshootingAppendix List of Figures Viii Teledyne Analytical InstrumentsCombustible GAS Usage Introduction Model IntroductionIntroduction Features Portable Trace Oxygen Analyzer IntroductionIntroduction Model Micro-Fuel Cell Cell WarrantyMethod of Analysis Compact Packaging Signal OutputAccuracy and Response Portable Trace Oxygen Analyzer Introduction Intentionally left blank Charging the Batteries InstallationPortable Trace Oxygen Analyzer Installation Installation Model Gas ConnectionsPortable Trace Oxygen Analyzer Installation Sensor Installation Installing a Trace SensorCalibration Procedure for Trace Analysis CalibrationSet the Sample Flow rate Bleeding the Regulator and Purging the Gas LineExternal Signal Operation Front Panel InterfaceOperation Model Enter Key3 UP/DOWN Keys Portable Trace Oxygen Analyzer OperationEscape Key Operation and Setup Screens and Menus Available Menus and Their SequenceDate Screen Power on ScreenHome Screen Enter Time ScreenStandard Alarm Screen Alarm EnableFS Alarm Screen HI-LOW Alarm ScreenLtch Alarm Screen Range 1 Screen Range 2 ScreenRange Screen Span Value Screen Span ScreenFilter Screen LOG Reset & Start Screen LOG Intv ScreenLOG Transmit Screen Power Down Screen Portable Trace Oxygen Analyzer Operation Maintenance & Troubleshooting Routine MaintenanceReplacing the Battery Maintenance ModelBattery Power Supply Service Portable Trace Oxygen Analyzer MaintenanceCell Replacement Battery Charger Port on the ModelCell Warranty Temperature Compensation Effect of CO2 on B-2 Cell Life Effects of CO2 on B-2 Cell LifeLeak Testing ProcedureIntentionally left blank Appendix Model SpecificationsAppendix Spare Parts List Portable Trace Oxygen Analyzer AppendixIndex Power Down screen, 39 power off Portable Trace Oxygen Analyzer IndexAppendix Model

3110 specifications

The Teledyne 3110 is a sophisticated, high-performance data acquisition and analysis system that has garnered attention in a range of scientific and industrial applications. Designed with advanced technologies, the Teledyne 3110 is optimized for versatility, enabling users to gather and analyze data from various sources with seamless integration.

One of the main features of the Teledyne 3110 is its modular design. This allows users to customize the system to meet their specific needs by adding or removing modules as necessary. It supports a wide range of input types, making it compatible with numerous sensors and devices, which enhances its utility in diverse environments.

The device boasts high precision and accuracy in data collection, which is crucial for applications where minute measurements matter. The instrument employs cutting-edge analog-to-digital converters, ensuring that data is captured with remarkable fidelity. Additionally, the Teledyne 3110 incorporates advanced signal processing technologies that improve data quality and reduce noise, facilitating clearer and more reliable analysis results.

Another key characteristic of the Teledyne 3110 is its user-friendly interface. The system comes equipped with intuitive software for data visualization and analysis, allowing users, even those with limited technical experience, to navigate the system efficiently. With comprehensive data export options, users can easily integrate the system's outputs into other software for further analysis and reporting.

Durability and reliability are also hallmarks of the Teledyne 3110. Built to endure harsh environments, the system is tested rigorously to ensure it meets high standards for protection against dust, moisture, and temperature variations. This robustness makes it applicable in fields such as environmental monitoring, industrial automation, and research laboratories.

Furthermore, the Teledyne 3110 supports real-time monitoring and data logging capabilities. This feature is essential for applications that require continuous oversight and data collection to respond promptly to any changes in conditions or parameters being monitored.

In summary, the Teledyne 3110 stands out as a versatile and reliable data acquisition system, leveraging modularity, precision, user-friendliness, and durability to serve a variety of applications effectively. Whether for research, industrial applications, or environmental monitoring, the Teledyne 3110 proves to be an invaluable tool for professionals seeking high-quality data insights.