Teledyne 3110 operating instructions Specifications, Appendix Model

Page 48

Appendix

Model 3110

 

 

Appendix

A.1 Specifications

TAI Sales Order Number:

Instrument Serial Number:

Micro-fuel Cell Class: B-2, A-2C, B-2CXL, Insta Trans Ranges of Analysis: 2 user defined ranges*

Accuracy: ±2% of scale or ±1 PPM (whichever is greater) at constant temperature;

±5% of reading or ±1 PPM (whichever is greater) over the operating temperature range.

Operating Temp. Range:

0 °C to 40 °C (32 °F to 104 °F)

Sample Temp. Range:

0-40°C

Sample Flow rate:

0.5 – 2.5 SCFH

Recommended Span Gas:

80-90% of range most likely to be used

Signal Output:

0-1VDC

Dimensions:

10.9” x 6.2” x 5.2” deep

Weight:

4.38 lbs. (1.99kg.)

Power Requirements:

100-240 VAC 47-63H Charging Adapter

* In auto range mode only

48 Teledyne Analytical Instruments

Image 48 Contents
Model Teledyne Analytical InstrumentsModel Ii Teledyne Analytical InstrumentsSpecific Model Information Portable Trace Oxygen AnalyzerSafety Messages Iv Teledyne Analytical InstrumentsPortable Trace Oxygen Analyzer Table of Contents Maintenance & Troubleshooting AppendixIndex Teledyne Analytical Instruments List of Figures Viii Teledyne Analytical InstrumentsCombustible GAS Usage Introduction IntroductionIntroduction Model Features Portable Trace Oxygen Analyzer IntroductionIntroduction Model Cell Warranty Method of AnalysisMicro-Fuel Cell Signal Output Accuracy and ResponseCompact Packaging Portable Trace Oxygen Analyzer Introduction Intentionally left blank Installation Portable Trace Oxygen Analyzer InstallationCharging the Batteries Installation Model Gas ConnectionsPortable Trace Oxygen Analyzer Installation Sensor Installation Installing a Trace SensorCalibration Procedure for Trace Analysis CalibrationSet the Sample Flow rate Bleeding the Regulator and Purging the Gas LineExternal Signal Operation Front Panel InterfaceOperation Model Enter KeyPortable Trace Oxygen Analyzer Operation Escape Key3 UP/DOWN Keys Operation and Setup Screens and Menus Available Menus and Their SequencePower on Screen Home ScreenDate Screen Enter Time ScreenStandard Alarm Screen Alarm EnableFS Alarm Screen HI-LOW Alarm ScreenLtch Alarm Screen Range 1 Screen Range 2 ScreenRange Screen Span Value Screen Span ScreenFilter Screen LOG Reset & Start Screen LOG Intv ScreenLOG Transmit Screen Power Down Screen Portable Trace Oxygen Analyzer Operation Maintenance & Troubleshooting Routine MaintenanceReplacing the Battery Maintenance ModelBattery Power Supply Service Portable Trace Oxygen Analyzer MaintenanceCell Replacement Battery Charger Port on the ModelCell Warranty Temperature Compensation Effect of CO2 on B-2 Cell Life Effects of CO2 on B-2 Cell LifeLeak Testing ProcedureIntentionally left blank Specifications AppendixAppendix Model Spare Parts List Portable Trace Oxygen Analyzer AppendixIndex Power Down screen, 39 power off Portable Trace Oxygen Analyzer IndexAppendix Model