Teledyne 3300TB operating instructions Appendix Specifications, Trace Oxygen Analyzer Appendix

Page 37

Trace Oxygen Analyzer

Appendix

 

 

 

 

 

 

 

 

 

Appendix

A.1 Specifications

Ranges:

Two user selectable ranges can be set

 

between 0-10 ppm and 0-9999 ppm

 

oxygen, and a 0-25 % (nominal) Air Cali-

 

bration Range.

SignalOutput:

Voltage: 0–10 V dc, negative ground

 

Current: 4-20 mA, negative ground

Range ID:

0-10 V dc.

Display:

Light emitting diode (LED)display.

Alarms:

One high alarm relay, adjustable; one low

 

alarm relay, adjustable; one sensor failure

 

relay. (All are failsafe.)

System Operating Temp:

0-50 °C

Accuracy:

±2 % of full scale at constant temperature

 

±5 % of full scale through operating tem-

 

perature range (At 100 ppm and higher user

 

defined ranges) once temperature equilib-

 

rium is reached.

 

±1 ppm for 10 ppm range under above

 

conditions.

Response Time:

90 % in less than 65 seconds at 25 °C

 

(68 °F).

System Power Requirement:

AC (100-240 VAC, 50/60Hz), or

 

DC (10-36 VDC); user specified.

System Enclosure:

Wall Mount, NEMA -4 Enclosure:

 

16.40" H × 8.0" W × 6.0" D (416.56 mm ×

 

203.2 mm × 152.40 mm).

Teledyne Analytical Instruments

A-1

Image 37
Contents Model 3300TB Copyright 1999 Teledyne Analytical Instruments Contents Appendix MaintenanceProtective Earth Combustible GAS Usage Warning Introduction Overview Main Features of the AnalyzerTrace Oxygen Analyzer Introduction Front Panel Description Set AlarmIntroduction Model 3300TB Rear Panel Rear Panel DescriptionRS-232 Port Analog OutputsMicro-Fuel Cell Sensor Operational Theory IntroductionTrace Oxygen Analyzer Operational Theory Principles of OperationAnatomy of a Micro-Fuel Cell Operational Theory Model 3300TBEffect of Pressure Electrochemical ReactionsCharacteristic Input/Output Curve for a Micro-Fuel Cell Calibration CharacteristicsElectronics Signal ProcessingGeneral Operational Theory Model 3300TB Trace Oxygen Analyzer Installation InstallationUnpacking the Analyzer Control Unit Installation Installation Model 3300TBInstalling the Micro-Fuel Cell / Cell Block Orientation Location and MountingElectrical Connections Electrical Connectors for AC Control UnitContact ID for Failsafe Relay Operation Alarm #2 Alarm #1Gas Connections Sensor FailPiping Diagram for Vacuum Service Option Installation Model 3300TB Vacuum Service OptionInstallation Checklist Installation Model 3300TB Trace Oxygen Analyzer Operation Operation IntroductionSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 3300TB Set Alarm Setting the Alarm SetpointsTrace Oxygen Analyzer Operation HI Range LO RangeSensor Fail Alarm Calibration Selecting a Fixed Range or AutorangingSupplementary Information Displaying Percent & PPM on the LED DisplayOperation Model 3300 TB Trace Oxygen Analyzer Maintenance MaintenanceRemove Power to Unit before replacing the fuse Replacing the FuseMaintenance Model 3300TB Sensor Installation or ReplacementWhen to Replace a Sensor Ordering and Handling of Spare SensorsExploded View of MFC and Cell Block Removing the Micro-Fuel CellDisconnect the Power Source from the Control Unit Installing a Micro-Fuel CellCell Warranty Conditions Trace Oxygen Analyzer Maintenance Maintenance Model 3300TB Trace Oxygen Analyzer Appendix Appendix SpecificationsAppendix Model 3300TB Spare Parts ListMiscellaneous Reference DrawingAppendix Model 3300TB Material Safety Data Sheet Primary route of entry Signs/symptoms of exposureExposure limits Osha PEL Effects of overexposure IngestionDisposal Protective measures