Teledyne 3300TB operating instructions Reference Drawing, Miscellaneous

Page 39

Trace Oxygen Analyzer

Appendix

 

 

 

 

 

 

 

 

 

A.3 Reference Drawing

D-70361 Outline Diagram

D-70362 Final Assembly

A.4 Miscellaneous

The symbol: ~ is used on the rear panel of the model 3300TB to signify volts alternating current (VAC).

NOTE: The MSDS on this material is available upon request through the Teledyne Environmental, Health and Safety Coordinator. Contact at (626) 934-1592

Teledyne Analytical Instruments

A-3

Image 39
Contents Model 3300TB Copyright 1999 Teledyne Analytical Instruments Contents Appendix MaintenanceProtective Earth Combustible GAS Usage Warning Main Features of the Analyzer Introduction OverviewTrace Oxygen Analyzer Introduction Set Alarm Front Panel DescriptionIntroduction Model 3300TB Rear Panel Rear Panel DescriptionRS-232 Port Analog OutputsPrinciples of Operation Operational Theory IntroductionMicro-Fuel Cell Sensor Trace Oxygen Analyzer Operational TheoryAnatomy of a Micro-Fuel Cell Operational Theory Model 3300TBEffect of Pressure Electrochemical ReactionsCharacteristic Input/Output Curve for a Micro-Fuel Cell Calibration CharacteristicsSignal Processing ElectronicsGeneral Operational Theory Model 3300TB Installation Trace Oxygen Analyzer InstallationUnpacking the Analyzer Location and Mounting Installation Model 3300TBControl Unit Installation Installing the Micro-Fuel Cell / Cell Block OrientationElectrical Connections Electrical Connectors for AC Control UnitContact ID for Failsafe Relay Operation Sensor Fail Alarm #1Alarm #2 Gas ConnectionsPiping Diagram for Vacuum Service Option Installation Model 3300TB Vacuum Service OptionInstallation Checklist Installation Model 3300TB Trace Oxygen Analyzer Operation Operation IntroductionUsing the Function and Data Entry Buttons Setting the Analysis RangesOperation Model 3300TB LO Range Setting the Alarm SetpointsSet Alarm Trace Oxygen Analyzer Operation HI RangeSensor Fail Alarm Calibration Selecting a Fixed Range or AutorangingDisplaying Percent & PPM on the LED Display Supplementary InformationOperation Model 3300 TB Replacing the Fuse MaintenanceTrace Oxygen Analyzer Maintenance Remove Power to Unit before replacing the fuseOrdering and Handling of Spare Sensors Sensor Installation or ReplacementMaintenance Model 3300TB When to Replace a SensorExploded View of MFC and Cell Block Removing the Micro-Fuel CellInstalling a Micro-Fuel Cell Disconnect the Power Source from the Control UnitCell Warranty Conditions Trace Oxygen Analyzer Maintenance Maintenance Model 3300TB Trace Oxygen Analyzer Appendix Appendix SpecificationsAppendix Model 3300TB Spare Parts ListMiscellaneous Reference DrawingAppendix Model 3300TB Material Safety Data Sheet Effects of overexposure Ingestion Signs/symptoms of exposurePrimary route of entry Exposure limits Osha PELDisposal Protective measures