1 Introduction

Model 3300TB

 

 

 

 

 

 

 

 

 

Three analog outputs: two for measurement (0–10 V dc, and negative ground 4–20 mA dc) and one for range identification (0-10 V dc).

Compact and rugged Control Unit, wall mounted NEMA-4 rated enclosure.

RS-232 Serial Digital port for output of concentration and data to a computer terminals, or other digital devices.

ASampleflowcontrolvalve.

1.3Front Panel Description

All controls except the power switch are accessible from the door and gas panel. See Figure 1-1. The front panel has seven pushbutton membrane switches, a digital meter, and an alarm indicator LED for operating the analyzer. These features are described briefly here and in greater detail in Chapter 4, Operation.

Figure 1-1: Front Panel

Function Keys: Seven pushbutton membrane switches are used to select the function performed by the analyzer:

Set Alarm 1

Set Alarm 1 Hi or Low, and the concentration at

 

which alarm 1 activates.

Set Alarm 2 Set the Alarm 2 Hi or Low, and the concentration to which alarm 2 activates.

1-2

Teledyne Analytical Instruments

Image 8
Contents Model 3300TB Copyright 1999 Teledyne Analytical Instruments Contents Maintenance AppendixProtective Earth Combustible GAS Usage Warning Trace Oxygen Analyzer Introduction Main Features of the AnalyzerIntroduction Overview Introduction Model 3300TB Set AlarmFront Panel Description Rear Panel Description Rear PanelAnalog Outputs RS-232 PortOperational Theory Introduction Micro-Fuel Cell SensorTrace Oxygen Analyzer Operational Theory Principles of OperationOperational Theory Model 3300TB Anatomy of a Micro-Fuel CellElectrochemical Reactions Effect of PressureCalibration Characteristics Characteristic Input/Output Curve for a Micro-Fuel CellGeneral Signal ProcessingElectronics Operational Theory Model 3300TB Unpacking the Analyzer InstallationTrace Oxygen Analyzer Installation Installation Model 3300TB Control Unit InstallationInstalling the Micro-Fuel Cell / Cell Block Orientation Location and MountingElectrical Connectors for AC Control Unit Electrical ConnectionsContact ID for Failsafe Relay Operation Alarm #1 Alarm #2Gas Connections Sensor FailInstallation Model 3300TB Vacuum Service Option Piping Diagram for Vacuum Service OptionInstallation Checklist Installation Model 3300TB Operation Introduction Trace Oxygen Analyzer OperationOperation Model 3300TB Using the Function and Data Entry ButtonsSetting the Analysis Ranges Setting the Alarm Setpoints Set AlarmTrace Oxygen Analyzer Operation HI Range LO RangeSensor Fail Alarm Selecting a Fixed Range or Autoranging CalibrationOperation Model 3300 TB Displaying Percent & PPM on the LED DisplaySupplementary Information Maintenance Trace Oxygen Analyzer MaintenanceRemove Power to Unit before replacing the fuse Replacing the FuseSensor Installation or Replacement Maintenance Model 3300TBWhen to Replace a Sensor Ordering and Handling of Spare SensorsRemoving the Micro-Fuel Cell Exploded View of MFC and Cell BlockCell Warranty Conditions Installing a Micro-Fuel CellDisconnect the Power Source from the Control Unit Trace Oxygen Analyzer Maintenance Maintenance Model 3300TB Appendix Specifications Trace Oxygen Analyzer AppendixSpare Parts List Appendix Model 3300TBReference Drawing MiscellaneousAppendix Model 3300TB Material Safety Data Sheet Signs/symptoms of exposure Primary route of entryExposure limits Osha PEL Effects of overexposure IngestionProtective measures Disposal