Omega Engineering OS533, OS530HR, OS531, OS53X-CF, OS524, OS532, OS530L, OS523 manual Display Details Key

Page 13

1General Description

Figure 1-2. Display and Keypad View

1

 

 

 

2

 

 

 

 

3

10

LCK

HAL

LOBAT

4

ATC

LAL

PRN °F °C

 

 

 

 

5

9

 

 

 

6

8

 

 

 

7

Table 1-2. Display Details

Key

Description

Display Mode displays one of the following:

 

 

TC (Thermocouple Input)

 

E (Emissivity)

HAL (High Alarm Setpoint)

 

MAX (Maximum Temperature)

LAL (Low Alarm Setpoint)

 

MIN (Minimum Temperature)

AMB (Ambient Target Temp)

 

dIF (Differential Temperature)

PRN (Print Data)

 

AVG (Average Temperature)

MEM (Store Temperature Data)

 

 

Data associated with one of the Display Modes

Backlighting Icon - allows the display to be viewed under low ambient light

Displays the units of measure in either °F or °C

Main display - displays the current temperature

Locks the trigger / Enables or Disables alarms

▲ for incrementing data;

is for turning on/off the backlighting

▼ for decrementing data;

is for changing the units of measure from °F to °C or vice versa

Function key for scrolling through the display modes

Display Icons

 

 

Trigger Lock

 

Low Alarm

 

 

Ambient Target

 

Low Battery

 

 

 

 

 

High Alarm

 

Print Data

 

 

 

 

 

 

 

 

LAL, AMB, PRN: OS533, OS534, OS523, OS524

 

 

 

 

 

 

 

TC: OS532, OS533, OS534

 

 

MEM: OS534, OS523, OS524

 

 

1-6

Image 13
Contents User’s Guide For immediate technical or application assistance Servicing North AmericaServicing Europe Unpacking Instructions Model No Description Page Unpacking Instructions Chapter General Description Contents General Description Introduction Features OS531 OS532 OS533 OS534 OS530HR OS530L-CF Features OS523 OS524 Front of the Thermometer Parts of the ThermometerDisplay Details Key OS530 Series Handheld Infrared Thermometer Rear View Rear of the ThermometerGeneral Description Ac Power Operation Battery OperationOS530/OS520 Series with Built-in Laser Sighting Operating the ThermometerField of View OS531, OS532, OS530L Field of View OS534, OS523-1 Field of View OS523-2 10 Field of View OS524 Trigger Measurement Techniques11 Recorder Hookup If the trigger is pulled two times in rapid sequence Real Time Mode Active OperationRecall Mode 13. Visual Function Flow Chart Using the Lock Function Adjusting EmissivityChanging the Temperature from F to C or vice versa Calculating Temperature ValuesTurning on the Display Backlighting Thermocouple Input OS532, OS533, OS534 If you are not in High Alarm Display Mode HAL when Using the Alarm FunctionsTo set the low alarm value OS533, OS534, OS523, OS524 To disable this mode, press the key again Icon disappears One Stop Bit Key to decrement the printing interval. System Requirements Irtempsoft Connecting the IR-System to the PC Using the Handheld Infrared Thermometer Storing the Temperature Data on Command OS534, OS523, OS524 Erasing the Temperature Data from Memory Mode Recall Mode Passive OperationFunctional Flow Chart Recall Mode Reviewing the Last Parameters AMB temperature MEM locationPRN F Using the Handheld Infrared Thermometer Laser Sighting Rear View DescriptionLaser Dot Operating the Laser SightingLines of Sight of the Laser Sighting and Thermometer Sighting Scope Installing and Operating the Sighting ScopeInstalling the Sighting Scope Maintenance Replacing the Batteries Safety WarningCalibrating the Thermometer Cleaning the LensServicing the Laser Sighting Problem Solution Troubleshooting GuideProblem If you see an error code, either Target are offset by design Specifications Specifications are for all models except where notedOS533, OS534, OS523, OS524 No Laser Sighting 17 hours continuous Laser Sighting Glossary of Key Strokes Glossary of Key Strokes Appendix How Infrared Thermometry Works a Thermal RadiationBlackbody Calculating Temperature Optics Field of View Appendix Emissivity Values MetalsMaterial Emissivity ε NonmetalsAppendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop online at omega.com