Omega Engineering OS534, OS530HR, OS531, OS53X-CF Cleaning the Lens, Calibrating the Thermometer

Page 53

5Maintenance

5.2 Cleaning the Lens

Although all lenses are quite durable, take care to prevent scratching when cleaning them. To clean the lens:

1.Blow off loose particles, using clean air.

2.Gently brush off remaining particles, using a camel hair brush. Alternatively, clean any remaining contaminants with a damp, soft, clean cloth. Be careful not to rub too hard.

CAUTION

Do not use any ammonia or cleaners with ammonia on the lens, as damage may result. Do not wipe the surface dry, as this may cause scratching.

5.3 Calibrating the Thermometer

The thermometer can not be calibrated by the user. For precise calibration of the thermometer, call our Customer Service Department. It is recommended that the Infrared Thermometer to be sent to the factory once a year for recalibration.

5.4 Servicing the Laser Sighting

Servicing and maintenance is not required to keep the laser sighting in proper operating condition. In the event of a malfunction, the unit should be returned to the manufacturer for repair.

5-2

Image 53
Contents User’s Guide Servicing Europe Servicing North AmericaFor immediate technical or application assistance Unpacking Instructions Model No Description Page Unpacking Instructions Chapter General Description Contents General Description Introduction Features OS531 OS532 OS533 OS534 OS530HR OS530L-CF Features OS523 OS524 Front of the Thermometer Parts of the ThermometerDisplay Details Key OS530 Series Handheld Infrared Thermometer Rear View Rear of the ThermometerGeneral Description Ac Power Operation Battery OperationOS530/OS520 Series with Built-in Laser Sighting Operating the ThermometerField of View OS531, OS532, OS530L Field of View OS534, OS523-1 Field of View OS523-2 10 Field of View OS524 Trigger Measurement Techniques11 Recorder Hookup If the trigger is pulled two times in rapid sequence Real Time Mode Active OperationRecall Mode 13. Visual Function Flow Chart Using the Lock Function Adjusting EmissivityTurning on the Display Backlighting Calculating Temperature ValuesChanging the Temperature from F to C or vice versa Thermocouple Input OS532, OS533, OS534 If you are not in High Alarm Display Mode HAL when Using the Alarm FunctionsTo set the low alarm value OS533, OS534, OS523, OS524 To disable this mode, press the key again Icon disappears One Stop Bit Key to decrement the printing interval. System Requirements Irtempsoft Connecting the IR-System to the PC Using the Handheld Infrared Thermometer Storing the Temperature Data on Command OS534, OS523, OS524 Erasing the Temperature Data from Memory Mode Recall Mode Passive OperationFunctional Flow Chart Recall Mode Reviewing the Last Parameters AMB temperature MEM locationPRN F Using the Handheld Infrared Thermometer Laser Sighting Rear View DescriptionLaser Dot Operating the Laser SightingLines of Sight of the Laser Sighting and Thermometer Sighting Scope Installing and Operating the Sighting ScopeInstalling the Sighting Scope Maintenance Replacing the Batteries Safety WarningServicing the Laser Sighting Cleaning the LensCalibrating the Thermometer Problem Solution Troubleshooting GuideProblem If you see an error code, either Target are offset by design Specifications Specifications are for all models except where notedOS533, OS534, OS523, OS524 No Laser Sighting 17 hours continuous Laser Sighting Glossary of Key Strokes Glossary of Key Strokes Appendix How Infrared Thermometry Works a Thermal RadiationBlackbody Calculating Temperature Optics Field of View Appendix Emissivity Values MetalsMaterial Emissivity ε NonmetalsAppendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop online at omega.com