Omega Engineering OS532, OS530HR, OS531, OS53X-CF, OS524, OS533, OS530L, OS523, OS534 Recorder Hookup

Page 23

2Using the Handheld Infrared Thermometer

NOTE

Center hole is the

analog output jack

Analog

Cable

To Strip Chart

Recorder

Figure 2-11 Recorder Hookup

Moving Surface Scan - Measures the Temperature of Points on a Moving Surface:

1.Mount the thermometer on a camera tripod and aim at a fixed point on the moving surface.

2.Pull the trigger and press the key to lock the trigger.

3.If necessary, adjust the emissivity. The thermometer is now set up for measuring the temperature of a moving surface.

4.To record the temperature profile of the moving surface, connect the IR thermometer to a strip chart recorder. Refer to Figure 2-11 for details.

5.After all data is taken, press the key to unlock the trigger.

Fixed Point Monitoring Over Time - Monitors the temperature at a fixed point over time:

NOTE

It is recommended that you use the ac adapter for long term measurement of temperature.

1.Mount the thermometer on a camera tripod and aim at the target.

2.Connect the analog output of the thermometer to a strip chart recorder as shown in Figure 2-11.

3.Pull the trigger and press the key to lock the trigger.

4.If necessary, adjust the emissivity.

5.The thermometer is now set up for unattended monitoring of temperature over time. You can also download the temperature to a Serial Printer or a PC for further analysis (Models OS533, OS534, OS523, OS524).

6.After all data is taken, press the key to unlock the trigger.

2-8

Image 23
Contents User’s Guide Servicing Europe Servicing North AmericaFor immediate technical or application assistance Unpacking Instructions Model No Description Page Unpacking Instructions Chapter General Description Contents General Description Introduction Features OS531 OS532 OS533 OS534 OS530HR OS530L-CF Features OS523 OS524 Front of the Thermometer Parts of the ThermometerDisplay Details Key OS530 Series Handheld Infrared Thermometer Rear View Rear of the ThermometerGeneral Description Ac Power Operation Battery OperationOS530/OS520 Series with Built-in Laser Sighting Operating the ThermometerField of View OS531, OS532, OS530L Field of View OS534, OS523-1 Field of View OS523-2 10 Field of View OS524 Trigger Measurement Techniques11 Recorder Hookup If the trigger is pulled two times in rapid sequence Real Time Mode Active OperationRecall Mode 13. Visual Function Flow Chart Using the Lock Function Adjusting EmissivityTurning on the Display Backlighting Calculating Temperature ValuesChanging the Temperature from F to C or vice versa Thermocouple Input OS532, OS533, OS534 If you are not in High Alarm Display Mode HAL when Using the Alarm FunctionsTo set the low alarm value OS533, OS534, OS523, OS524 To disable this mode, press the key again Icon disappears One Stop Bit Key to decrement the printing interval. System Requirements Irtempsoft Connecting the IR-System to the PC Using the Handheld Infrared Thermometer Storing the Temperature Data on Command OS534, OS523, OS524 Erasing the Temperature Data from Memory Mode Recall Mode Passive OperationFunctional Flow Chart Recall Mode Reviewing the Last Parameters AMB temperature MEM locationPRN F Using the Handheld Infrared Thermometer Laser Sighting Rear View DescriptionLaser Dot Operating the Laser SightingLines of Sight of the Laser Sighting and Thermometer Sighting Scope Installing and Operating the Sighting ScopeInstalling the Sighting Scope Maintenance Replacing the Batteries Safety WarningServicing the Laser Sighting Cleaning the LensCalibrating the Thermometer Problem Solution Troubleshooting GuideProblem If you see an error code, either Target are offset by design Specifications Specifications are for all models except where notedOS533, OS534, OS523, OS524 No Laser Sighting 17 hours continuous Laser Sighting Glossary of Key Strokes Glossary of Key Strokes Appendix How Infrared Thermometry Works a Thermal RadiationBlackbody Calculating Temperature Optics Field of View Appendix Emissivity Values MetalsMaterial Emissivity ε NonmetalsAppendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop online at omega.com