Omega Engineering OS531, OS53X-CF, OS524, OS533, OS532, OS523, OS534 manual OS530HR OS530L-CF

Page 10

General Description 1

Features

OS530L

OS530HR

OS530L-CF

OS533-CF

OS534-CF

Accuracy*

±1% rdg

3°F (1.7 °C)

±1% rdg

±1% rdg

±1% rdg

Range

-18 to 538°C

-30 to 121°C

-18 to 538°C

-18 to 538°C

-18 to 871°C

 

0 to 1000°F

-22 to 250°F

0 to 1000°F

0 to 1000°F

0 to 1600°F

Emissivity

Adjustable

Adjustable

Adjustable

Adjustable

Adjustable

Display Resolution

1°F or 1°C

0.1°For 0.1°C

1°F or 1°C

1°F or 1°C

1°F or 1°C

Backlit Dual

std

std

std

std

std

Display

 

 

 

 

 

Field of view

10:1

20:1

.15"@6"

.15"@6"

.15"@6"

Differential

std

std

std

std

std

Temperature

Min/Max

std

std

std

std

std

Temperature

Average

std

std

std

std

std

Temperature

High Alarm

std

std

std

std

std

Low Alarm

---

---

---

std

std

Audible Buzzer

std

std

std

std

std

& Indicator

Ambient Target

---

---

---

std

std

Temp

Compensation

 

 

 

 

 

Analog Output

1 mV/Deg

1 mV/Deg

1 mV/Deg

1 mV/Deg

1 mV/Deg

RS232 Output

---

---

---

std

std

Data Storage

---

---

---

---

std

Built-in Laser

Dot/Circle

Dot/Circle

Dot

Dot

Dot

sighting

 

 

 

 

 

Trigger Lock

std

std

std

std

std

Last Temperature

std

std

std

std

std

Recall

Thermocouple

---

---

---

std

std

Input

*The temperature accuracy is 1% or 2% of Rdg or 3ºF (2ºC) whichever is greater.

1-3

Image 10
Contents User’s Guide For immediate technical or application assistance Servicing North AmericaServicing Europe Unpacking Instructions Model No Description Page Unpacking Instructions Chapter General Description Contents General Description Introduction Features OS531 OS532 OS533 OS534 OS530HR OS530L-CF Features OS523 OS524 Parts of the Thermometer Front of the ThermometerDisplay Details Key Rear of the Thermometer OS530 Series Handheld Infrared Thermometer Rear ViewGeneral Description Battery Operation Ac Power OperationOperating the Thermometer OS530/OS520 Series with Built-in Laser SightingField of View OS531, OS532, OS530L Field of View OS534, OS523-1 Field of View OS523-2 10 Field of View OS524 Measurement Techniques Trigger11 Recorder Hookup Real Time Mode Active Operation If the trigger is pulled two times in rapid sequenceRecall Mode 13. Visual Function Flow Chart Adjusting Emissivity Using the Lock FunctionChanging the Temperature from F to C or vice versa Calculating Temperature ValuesTurning on the Display Backlighting Thermocouple Input OS532, OS533, OS534 Using the Alarm Functions If you are not in High Alarm Display Mode HAL whenTo set the low alarm value OS533, OS534, OS523, OS524 To disable this mode, press the key again Icon disappears One Stop Bit Key to decrement the printing interval. System Requirements Irtempsoft Connecting the IR-System to the PC Using the Handheld Infrared Thermometer Storing the Temperature Data on Command OS534, OS523, OS524 Erasing the Temperature Data from Memory Recall Mode Passive Operation ModeFunctional Flow Chart Recall Mode AMB temperature MEM location Reviewing the Last ParametersPRN F Using the Handheld Infrared Thermometer Laser Sighting Description Rear ViewOperating the Laser Sighting Laser DotLines of Sight of the Laser Sighting and Thermometer Installing and Operating the Sighting Scope Sighting ScopeInstalling the Sighting Scope Safety Warning Maintenance Replacing the BatteriesCalibrating the Thermometer Cleaning the LensServicing the Laser Sighting Troubleshooting Guide Problem SolutionProblem If you see an error code, either Target are offset by design Specifications are for all models except where noted SpecificationsOS533, OS534, OS523, OS524 No Laser Sighting 17 hours continuous Laser Sighting Glossary of Key Strokes Glossary of Key Strokes Thermal Radiation Appendix How Infrared Thermometry Works aBlackbody Calculating Temperature Optics Field of View Metals Appendix Emissivity ValuesNonmetals Material Emissivity εAppendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER Shop online at omega.com PH/CONDUCTIVITY