Omega Engineering OS53X-CF, OS530HR, OS531, OS524, OS533, OS532 manual If you see an error code, either

Page 56

Troubleshooting Guide 6

 

Problem

Solution

 

 

 

 

If you see an error code, either

 

 

“ERR1”, “ERR2”, or “ERR3”, record

 

 

the code and call our Customer

 

 

Service Department. Provide

 

 

 

 

Customer Service with the error

 

 

code that is displayed in the upper

 

 

left corner of the display. The

 

 

 

 

Customer Service Department

 

 

representative may ask you to return

 

 

the thermometer to the factory.

 

 

• The display will go back to the

 

 

Real Time Mode (Emissivity

 

 

 

 

Display Mode).

 

 

 

 

c. After running the diagnostic

 

 

program, press the

key to

 

 

unlock the trigger.

 

 

 

 

 

 

 

1. The thermometer has to stabilize

 

The temperature reading is

before taking temperature

 

 

 

erratic. The thermometer

measurements. It takes up to 40

 

has just been moved from

minutes for the thermometer to

 

one extreme temperature

stabilize.

 

 

 

to room temperature [0°C

 

 

 

 

or 50°C (32°F or 122°F)]

 

 

 

 

or vice versa.

 

 

 

 

 

 

 

 

1. The thermometer has to stabilize

 

The temperature reading

before taking temperature

 

 

 

is erratic. The thermometer

measurements. It takes up to 20

 

has just been moved from

minutes for the thermometer to

 

room temperature

stabilize.

 

 

(ambient temperature) to a temperature 10°C colder or warmer.

6-3

Image 56
Contents User’s Guide Servicing Europe Servicing North AmericaFor immediate technical or application assistance Unpacking Instructions Model No Description Page Unpacking Instructions Chapter General Description Contents General Description Introduction Features OS531 OS532 OS533 OS534 OS530HR OS530L-CF Features OS523 OS524 Parts of the Thermometer Front of the ThermometerDisplay Details Key Rear of the Thermometer OS530 Series Handheld Infrared Thermometer Rear ViewGeneral Description Battery Operation Ac Power OperationOperating the Thermometer OS530/OS520 Series with Built-in Laser SightingField of View OS531, OS532, OS530L Field of View OS534, OS523-1 Field of View OS523-2 10 Field of View OS524 Measurement Techniques Trigger11 Recorder Hookup Real Time Mode Active Operation If the trigger is pulled two times in rapid sequenceRecall Mode 13. Visual Function Flow Chart Adjusting Emissivity Using the Lock FunctionTurning on the Display Backlighting Calculating Temperature ValuesChanging the Temperature from F to C or vice versa Thermocouple Input OS532, OS533, OS534 Using the Alarm Functions If you are not in High Alarm Display Mode HAL whenTo set the low alarm value OS533, OS534, OS523, OS524 To disable this mode, press the key again Icon disappears One Stop Bit Key to decrement the printing interval. System Requirements Irtempsoft Connecting the IR-System to the PC Using the Handheld Infrared Thermometer Storing the Temperature Data on Command OS534, OS523, OS524 Erasing the Temperature Data from Memory Recall Mode Passive Operation ModeFunctional Flow Chart Recall Mode AMB temperature MEM location Reviewing the Last ParametersPRN F Using the Handheld Infrared Thermometer Laser Sighting Description Rear ViewOperating the Laser Sighting Laser DotLines of Sight of the Laser Sighting and Thermometer Installing and Operating the Sighting Scope Sighting ScopeInstalling the Sighting Scope Safety Warning Maintenance Replacing the BatteriesServicing the Laser Sighting Cleaning the LensCalibrating the Thermometer Troubleshooting Guide Problem SolutionProblem If you see an error code, either Target are offset by design Specifications are for all models except where noted SpecificationsOS533, OS534, OS523, OS524 No Laser Sighting 17 hours continuous Laser Sighting Glossary of Key Strokes Glossary of Key Strokes Thermal Radiation Appendix How Infrared Thermometry Works aBlackbody Calculating Temperature Optics Field of View Metals Appendix Emissivity ValuesNonmetals Material Emissivity εAppendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER Shop online at omega.com PH/CONDUCTIVITY