| Handlebars | If tests reveal no other issues, Handle- |
|
| bars should be replaced. |
Unit operates but Telemet- | Chest Strap (optional) | Strap should be “POLAR®” compat- |
ric HR not displayed |
| ible and uncoded. Make sure strap is |
|
| directly against skin and contact area |
|
| is wet. |
|
|
|
| Interference | Try moving unit away from sources of |
|
| interference (TV, Microwave, etc). |
|
|
|
| Replace Chest Strap | If interference is eliminated and HR |
|
| does not function, replace strap. |
|
|
|
| Replace Console | If HR still does not function, replace |
|
| Console. |
|
|
|
Console displays “E2” error | Check data cable integrity | All wires in cable should be intact. If any |
code |
| are cut or crimped, replace cable. |
|
|
|
| Check data cable | Be sure cable is connected securely |
| connections/orientation | and oriented properly. Small latch on |
|
| connector should line up and snap into |
|
| place. |
|
|
|
| Console Electronics | If tests reveal no other issues, Console |
|
| should be replaced. |
|
|
|
No speed/RPM reading, | Check data cable integrity | All wires in cable should be intact. If any |
Console displays “Please |
| are cut or crimped, replace cable. |
Pedal” error code |
|
|
|
|
|
| Check data cable | Be sure cable is connected securely |
| connections/orientation | and oriented properly. Small latch on |
|
| connector should line up and snap into |
|
| place. |
|
|
|
| Check magnet position | Magnet should be in place on pulley. |
| (requires shroud removal) |
|
|
|
|
| Check Speed Sensor (re- | Speed sensor should be aligned with |
| quires shroud removal) | magnet and connected to data cable. |
|
| Realign sensor if necessary. Replace if |
|
| there is any damage to the sensor or |
|
| the connecting wire. |
|
|
|
47