Tanita BC-570 instruction manual Preparations Before USE, Automatic SHUT-DOWN Function

Page 3

BC570/取説 06.12.1 6:51 PM ページ5

GB

PREPARATIONS BEFORE USE

 

Inserting the Batteries

Open as shown.

Turn the scale over and remove the battery cover by releasing the latch, install 2 pieces of new

 

battery (included) with correct polarity as indicated

 

Note: Be sure that the polarity of the batteries is set properly. If the batteries are

 

incorrectly positioned the fluid may leak and damage floors. If you do not intend to use this

Direction of the

unit for a long period of time, it is advisable to remove the batteries before storage.

batteries.

Please note that the included batteries from factory may have decreased energy levels

 

over time.

Positioning the Monitor

Place the measuring platform on a hard, flat surface where there is minimal vibration to ensure safe and accurate measurement.

Note: To avoid possible injury, do not step on the edge of the platform.

Handling Tips

This monitor is a precision instrument utilizing state-of-the-art technology. To keep the unit in the best condition, follow these instructions carefully: Do not attempt to disassemble the measuring platform.

Store the unit horizontally, and place it so that the buttons will not be pressed accidentally. Avoid excessive impact or vibration to the unit.

Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.

Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny; avoid soaps.

Do not step on the platform when wet.

Do not drop any objects onto the platform.

GETTING ACCURATE READINGS

GB

SETTING AND STORING PERSONAL DATA IN MEMORY

You will receive readings only if data has been programmed into one of the personal data memories or the Guest mode. The monitor can store personal details for up to 4 people.

1. Turn on the Power

Press the Set button to turn on the unit (once programmed, tapping a Personal Key turns on the unit.) The unit will beep to confirm activation, the Personal Key numbers (1,2,3,4) will be displayed, and the display will flash.

Note: If you don’t operate the unit for sixty seconds after the unit has been turned on, the unit

will turn off automatically.

Note: If you make a mistake or want to turn the unit off before you have finished programming it, press the Weight-Only Key

() to force quit.

2. Select a Personal Key Number

Press the Up/Down buttons to select a Personal Key. Once you reach the Personal Key number you wish to use, press the Set button. The unit will beep once to confirm.

3. Set Age

Heels centered on

Toes may overhang

electrodes

measuring platform

Note: An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a sitting position.

To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on the measuring platform. Be sure that your heels are correctly aligned with the electrodes on the measuring platform. Don't worry if your feet appear too large for the unit - accurate readings can still be obtained if your toes overhang the platform.

It is best to take readings at the same time of day. Try to wait about three hours after rising, eating, or hard exercise before taking measurements. While readings taken under other conditions may not have the same absolute values, they are accurate for determining the percentage of change as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat percentage taken under the same conditions over a period of time.

The display defaults to Age 30 (range of user age is between 5-99). An arrow icon appears on the lower left side to indicate Age setting. Use the Up/Down buttons to scroll through numbers. When you reach your age, press the Set button. The unit will beep once to confirm.

4. Select Female or Male

Use the Up/Down buttons to scroll through Female ( ) or Male (), Female/Athlete ( /) and Male/Athlete (/) settings, then press the Set button. The unit will beep once to confirm.

AUTOMATIC SHUT-DOWN FUNCTION

The automatic shut-down function shuts off the power automatically in the following cases:

If you interrupt the measurement process. The power will shut down automatically within 10 to 20 seconds, depending upon the type of operation.

If an extreme weight is applied to the platform.

During programming, if you do not touch any of the keys or buttons within 60 seconds.* After you have completed the measuring process.

*Note: If the power shuts off automatically, repeat the steps from “Setting and Storing Personal Data in Memory” (p.3).

SWITCHING THE WEIGHT MODE Note: For use only with models containing the weight mode switch

You can change the unit indication by using the switch on the back of the scale as shown in the figure.

Note: If weight mode is set to pounds or stone-pounds, the height programming mode will be automatically set to feet and inches. Similarly, if kilograms is selected, height will be automatically set to centimeters.

5. Specify the Height

The display defaults to 5’ 7.0” (170cm) (range of user is from 3’ 0.0”–7’ 3.0” or 90cm

– 220cm). Use the Up/Down buttons to specify Height and then press the Set button. The unit will beep once to confirm.

2

3

Image 3
Contents Lire attentivement et à garder en cas de besoin Model BC-570Important Notes for Users Features and FunctionsSafety Precautions IntroductionAutomatic SHUT-DOWN Function Preparations Before USEObtain Your Readings Taking Weight and Body FAT ReadingsProgramming the Guest Mode Taking Weight Measurement onlyTroubleshooting EinleitungMerkmale UND Funktionen Vorbereitungen VOR Gebrauch SO Erhalten SIE Genaue Messwerte Einstellung UND Speichern Persönlicher DatenMessung DER Körperzusammensetzung Einprogrammieren DES GastmodusNUR-GEWICHT-FUNKTION Caractéristiques Avant Utilisation Sollten die folgenden Probleme auftauchen,... dannWährend des Messens erscheint Error FehlersucheComment Obtenir DES Résultats Exacts Commutation DU Mode PoidsProgrammation DU Mode Invité Relevés DE Composition CorporelleLecture DU Poids Uniquement Introductie Eigenschappen EN Functies VoorbereidingsmaatregelenInleggen van batterijen Afleesnauwkeurighid Automatische UnitschakelfunctieVeranderen VAN Gewichtseenheid Lichaamssamenstelling Aflezen Gaststand OrogrammerenAlleen Geeicht Bepalen Caratteristiche E Funzionalitá Preparazioni Prima Delluso Error verschijnt tijdens de maatnemingFoutopsporing IntroduzioneCommutazione Della Modalità DI Peso Funzione DI Spegnimento AutomaticoFunzione di richiamo Gaststand ProgrammerenMisurazione DEL SOLO-PESO Ottenete le lettureRisoluzione DEI Problemi IntroducciónPrestaciones Y Funciones Preparaciones Antes DEL USO Cómo Obtener Lecturas Exactas Función DE Apagado AutomáticoCambiando EL Modo DEL Peso Función de recuperación de memoria Programación DEL Modo DE InvitadoCómo Obtener Lecturas DE Peso Solamente Observe sus medicionesResolución DE Fallos IntroduçãoCaracterísticas E Funções Preparativos Antes do USO Obtendo Leitura Precisa Funçào Desligamento AutomàticoAlterando a Unidade DE Medida do Peso Função Recuperar Efectuar Leituras DE Composição CorporalProgramando Modo Convidado Somente a Leitura do PesoAparece OL durante a medição Se ocorrer seguintes problemas... entãoAparece Error durante a medição Localizando DefeitosBC570/取説 06.12.1 651 PM ページ47

BC-570 specifications

The Tanita BC-570 is a sophisticated body composition analyzer designed to provide users with a comprehensive overview of their health metrics. This innovative scale combines advanced technology with user-friendly functionality, making it suitable for both personal use and clinical settings.

One of the standout features of the Tanita BC-570 is its ability to measure body fat percentage, muscle mass, and water percentage with accuracy. Utilizing foot-to-foot Bioelectrical Impedance Analysis (BIA) technology, the scale sends a low-level electrical current through the body. Since different tissues, such as fat, muscle, and water, conduct electricity differently, the scale can determine the composition of the user's body with precision.

Besides body fat and muscle mass, the Tanita BC-570 also calculates basal metabolic rate (BMR) and metabolic age. BMR reflects the minimum energy required to maintain vital functions at rest, while metabolic age is a comparison of one’s BMR to the average BMR for different age groups. This feature empowers users to understand how their metabolism compares to their chronological age.

The device has a user-friendly interface and a large, easy-to-read LCD screen that displays results in real time. It can store data for multiple users, making it ideal for families or fitness groups. With a memory capacity of up to 4 users, each individual can track their metrics over time, allowing for better goal setting and progress monitoring.

Another noteworthy characteristic of the Tanita BC-570 is its athlete mode. This feature is tailored for individuals who engage in regular training and have a lower body fat percentage. By adjusting the calculations to reflect the physiological differences in athletes, this mode offers a more accurate assessment of muscle mass and body fat.

Durability is also a significant factor, as the BC-570 is designed with a sturdy platform that can support a weight capacity of up to 330 pounds (150 kg). Its sleek design makes it a stylish addition to any home or gym setting.

In summary, the Tanita BC-570 is a versatile and advanced body composition scale that delivers accurate health metrics, features user-friendly technology and built-in functionalities, and benefits those aiming for improved fitness and well-being. Whether for personal tracking or professional use, it stands out as an essential tool for health management.