Emerson 5081FG instruction manual Diagnostics Menu, Show Fault, C mV

Page 53

Model 5081FG

Instruction Manual

IB-106-5081, Rev. 1.0 May 2005

%

26020017

Figure 3-20. SHOW FAULT

3-6 DIAGNOSTICS MENU

The DIAGNOSTICS MENU branch of the menu tree allows you to examine outputs, current faults, and unit information. None of the items in the DIAGNOSTICS MENU are editable. This branch of the menu tree may be accessed by pressing DIAG on the IRC when in the PROC- ESS DISPLAY screen (Normal or Faulted). Each screen in this branch is accessed sequen- tially by pressing NEXT. Refer to Figure 3-5during the following menu and screen descriptions.

a.SHOW FAULT

Refer to Figure 3-20. After pressing DIAG, this screen displays. Pressing ENTER ac- cesses a screen displaying the current fault (if any). If more than one fault exists, and you are in the FAULT screen, press NEXT to go to the next fault. Information on the fault screens can be found in Section 6, TROUBLESHOOTING. Press EXIT to re- turn from this fault sub-menu and press NEXT to access the T/C mV screen.

b.T/C mV

Refer to Figure 3-21. Use this screen to ex- amine the cell thermocouple mV output. Three decimal places are displayed. Press- ing NEXT accesses the O2 CELL mV screen.

%

3

THERMOCOUPLE mV

26020018

Figure 3-21. T/C mV

c.O2 CELL mV

Refer to Figure 3-22. Use this screen to ex- amine the O2 cell mV output. Pressing NEXT accesses the CELL IMPEDANCE screen.

%

O2 CELL mV

26020019

Figure 3-22. O2 CELL mV

Rosemount Analytical Inc. A Division of Emerson Process Management

Startup and Operation 3-11

Image 53
Contents Model 5081FG Essential Instructions Summary Highlights of ChangesEffective May, 2005 Rev Page Model 5081FG Table of ContentsList of Illustrations List of Tables Model 5081FG Definitions PrefaceModel 5081FG Belangrijk Vigtigt Model 5081FG Tärkeää Model 5081FG Wichtig Importante Viktig Model 5081FG Model 5081FG Viktigt Model 5081FG Component Checklist of Typical System Package Contents Section Description and SpecificationsCode Mounting Adapter Stack Side Product MatrixSystem Overview System ConfigurationScope System DescriptionSystem Features Handling the Analyzer System Considerations Transmitter Typical System InstallationProbe SpecificationsOhms Lift OFF Maximum Power Supply VoltageVDC Operating Load RegionPRE-INSTALLATION Section InstallationMechanical Installation InspectSide View Bottom View Front ViewMetal Wall Masonry Wall Stack or Duct Horizontal Probe Installation Adjusting Probe Insertion Depth Model 5081FG Installing Model 5081 Transmitter Circuit Terminal END Cover LockBlock TB Mounting HolesElectrical Installation Display Positioning AssemblyThermocouple CELL-WH CELL+BK Model 5081 Transmitter 4-20 mA and Signal ConnectionsTerminal Block Conduit Reference Air Package Pneumatic InstallationInstrument Air Reference Air Calibration Check GasOutlet Outlet ConnectionInlet Connection Flow SET MAX Point Knob Mounting HolesGeneral Power UPSection Startup and Operation Proper Calibration Check Gas Flow Rate Reestablishing Proper Calibration Check GAS Flow RateOverview OperationDisplay Menu TreeCalcheck DiagnosticsMenu ProgramNavigation Infrared Remote Control IRCAnalyzer Access Code O2 Concentration Analyzer Access Code Or SecurityProgram Menu O2 ConcentrationO2 Concentration Upper Cell Temperature Fault Value O2 Concentration Indicator Fault ValueUpper Range VAL Cell T HI To Reset Maximum Cell Temperature Reset MAX Cell T O2 Concentration Analyzer Access Code SET O2 Filter TimeConcentration SET HI Bottle O2SET LO Bottle O2 Model 5081 Transmitter Parameters SET Code Parameter Range DefaultModel 5081 Transmitter Parameters C mV Diagnostics MenuShow Fault 24. Previous Slope Previous Constant 23. Cell ImpedanceCalcheck Menu Accept LOW O2 27. in MANUAL?29. Accept LOW O2 Slope Model 5081FG Section HART/AMS Hart Communicator Signal LineOverview ConnectionsAnalog Output Device Method 2, For Load Resistance 250 OhmsHart Communicator PC TWO-WIRE in Situ Oxygen AnalyzerOFF-LINE and ON-LINE Operations Menu Tree for Hart CommunicatorDevice Setup From Sheet Basic Setup Detailed From Sheet Signal Condition Detailed Setup Output Hart Communicator Start CAL- Check Method Model 5081FG Model 5081 Electronics Replacement Section Maintenance and ServiceDisplay Board Replacement Spare Board Stack ReplacementRibbon Cable Analog Board CPU Two-Wire In Situ Oxygen Analyzer Exploded ViewOxygen Probe Replacement Oxygen Probe Terminal Block Probe Life Section TroubleshootingNormal Operational Conditions IMPEDANCE, ΩSpeed Fault IndicationsOfresponse Thermocouple Identifying and Correcting Fault IndicationsFault 1, Open Thermocouple Fault 3, Shorted Thermocouple Fault 5, O2 Cell Open Fault 6, Cell Impedance Too High Fault 5, O2 Cell Open11. Fault 7, Reversed O2 Cell Fault 7, Reversed O2 CellModel 5081FG Section Return of Material Model 5081FG Replacement Parts List Replacement PartsSection Index No Part Number DescriptionModel 5081FG Section Index Model 5081FG Model 5081FG Page Warranty Two-Wire In Situ Oxygen Analyzer Serial no Order no