Emerson 5081FG instruction manual From Sheet Signal Condition Detailed Setup Output

Page 64

Instruction Manual

IB-106-5081, Rev. 1.0 May 2005

Model 5081FG

DEVICE SETUP

O2 value

O2 output

LRV

URV

Device SN

Alarm Value

(CONTINUED FROM

 

(CONTINUED FROM

SHEET 2)

 

SHEET 2)

 

 

 

SIGNAL

CONDITION

DETAILED

SETUP

OUTPUT

CONDITION

Filter

DEVICE

INFORMATION

REVIEW

OUTPUTS

CONFIG

URV

LRV % rnge

ANALOG

OUTPUT

HART OUTPUT

Manufacturer Model

Dev id Tag Descriptor Message Date

Final asmbly num Snsr s/n

Fld dev rev Hardware rev Software rev Universal rev

URV

Filter Poll addr

Num req preams

O2 output

AO Alrm typ

LOOP TEST

D/A TRIM

Poll addr

Num req preams

Loop test method

D/A trim method

26020046

Figure 4-3. Menu Tree for HART/AMS on the Two-Wire In Situ Oxygen Analyzer (Sheet 3 of 3)

4-6 HART/AMS

Rosemount Analytical Inc. A Division of Emerson Process Management

Image 64
Contents Model 5081FG Essential Instructions Effective May, 2005 Rev Highlights of ChangesSummary Page Table of Contents Model 5081FGList of Illustrations List of Tables Model 5081FG Preface DefinitionsModel 5081FG Belangrijk Vigtigt Model 5081FG Tärkeää Model 5081FG Wichtig Importante Viktig Model 5081FG Model 5081FG Viktigt Model 5081FG Section Description and Specifications Component Checklist of Typical System Package ContentsProduct Matrix Code Mounting Adapter Stack SideSystem Configuration System OverviewScope System DescriptionSystem Features Handling the Analyzer System Considerations Typical System Installation TransmitterSpecifications ProbeLift OFF Maximum Power Supply Voltage OhmsVDC Operating Load RegionSection Installation PRE-INSTALLATIONMechanical Installation InspectFront View Side View Bottom ViewMetal Wall Masonry Wall Stack or Duct Horizontal Probe Installation Adjusting Probe Insertion Depth Model 5081FG Installing Model 5081 Transmitter Cover Lock Circuit Terminal ENDBlock TB Mounting HolesDisplay Positioning Assembly Electrical InstallationTerminal Block Conduit Model 5081 Transmitter 4-20 mA and Signal ConnectionsThermocouple CELL-WH CELL+BK Pneumatic Installation Reference Air PackageInstrument Air Reference Air Calibration Check GasOutlet Connection OutletInlet Connection Flow SET MAX Point Knob Mounting HolesSection Startup and Operation Power UPGeneral Reestablishing Proper Calibration Check GAS Flow Rate Proper Calibration Check Gas Flow RateOperation OverviewDisplay Menu TreeDiagnostics CalcheckMenu ProgramInfrared Remote Control IRC NavigationO2 Concentration Analyzer Access Code Or Security Analyzer Access CodeProgram Menu O2 ConcentrationO2 Concentration Indicator Fault Value O2 Concentration Upper Cell Temperature Fault ValueUpper Range VAL Cell T HIReset MAX Cell T To Reset Maximum Cell TemperatureO2 Concentration Analyzer Access Code SET O2 Filter TimeSET LO Bottle O2 SET HI Bottle O2Concentration Model 5081 Transmitter Parameters Parameter Range DefaultModel 5081 Transmitter Parameters SET Code Show Fault Diagnostics MenuC mV 23. Cell Impedance 24. Previous Slope Previous ConstantCalcheck Menu 27. in MANUAL? Accept LOW O229. Accept LOW O2 Slope Model 5081FG Hart Communicator Signal Line Section HART/AMSOverview ConnectionsMethod 2, For Load Resistance 250 Ohms Analog Output Device TWO-WIRE in Situ Oxygen Analyzer Hart Communicator PC OFF-LINE and ON-LINE Operations Menu Tree for Hart CommunicatorDevice Setup From Sheet Basic Setup Detailed From Sheet Signal Condition Detailed Setup Output Hart Communicator Start CAL- Check Method Model 5081FG Section Maintenance and Service Model 5081 Electronics ReplacementDisplay Board Replacement Spare Board Stack ReplacementTwo-Wire In Situ Oxygen Analyzer Exploded View Ribbon Cable Analog Board CPUOxygen Probe Replacement Oxygen Probe Terminal Block Section Troubleshooting Probe LifeNormal Operational Conditions IMPEDANCE, ΩOfresponse Fault IndicationsSpeed Identifying and Correcting Fault Indications ThermocoupleFault 1, Open Thermocouple Fault 3, Shorted Thermocouple Fault 5, O2 Cell Open Fault 5, O2 Cell Open Fault 6, Cell Impedance Too HighFault 7, Reversed O2 Cell 11. Fault 7, Reversed O2 CellModel 5081FG Section Return of Material Model 5081FG Replacement Parts Replacement Parts ListSection Index No Part Number DescriptionModel 5081FG Section Index Model 5081FG Model 5081FG Page Warranty Two-Wire In Situ Oxygen Analyzer Serial no Order no