If you are comfortable wearing your corrective lenses (contact lenses or eyeglasses) for microscope viewing, leave them

on and your adjustments will be minimal.

2.Using the fine focus adjusting knob, focus on the specimen while looking through only one of the eyepieces (when using one eyepiece that is focusable and one that is not focusable, look through the one that is not focusable). To help focus, cover or close the other eye.

3.Now look with the other eye just through the other eyepiece (focusing eyepiece). This time, focus the specimen by using the focu- sing capability in the focusing eyepiece.

When doing so, do not change the height of the specimen stage.

4.Grip the knurled ring on the focusing eyepiece with one hand and rotate the top of the eyepiece with the other hand until the specimen is in focus for this eye and this focusing eyepiece. This corrects for any

vision differences between your right eye and left eye.

5.Now, switch to an objective with a high magnification level (no oil objective) and bring the microscope into focus while looking through the eyepieces with both eyes.

The higher magnifications have a shallo- wer depth of field. Therefore, after focus- ing with a high magnification, you will find that

when you change to lower magnifications, you only have to adjust the fine focus slightly, if at all.

ϘϘ If you use a DM750 with standard illumi- nation, continue with the "Oil Immersion Technique" section on page 40.

ϘϘ If your DM750 has a Koehler configuration, please continue with the next section, "Koehler Configuration", on page 38.

Leica DM750

Manual

37

 

 

 

Image 37
Contents Leica DM750 Manual Manufacturer information Responsible for contentsPublished in November 2010 by Chapter overview Contents Safety regulations Safety concept Important information Light bulbsProvide clarity Explanatory notesImportant Notes Safety instructionsDescription Contact addressIntended Purpose of the Microscope Instructions on use So in the instructions For safety and potential hazardsPlace of use FungusScope of this manual Rights to any warranty claimsTransport DisposalHealth risks Health risks and dangers of useDual or detachable eyecups LED Klasse 1 /LED 1 Laser ProductInformation for the person responsible for the instrument Information for the person responsible for the instrumentCleaning glass surfaces Cleaning coated parts and plastic partsϘϘ Remove tough dirt using alcohol or petro- leum ether Care instructionsAccessories Accessories, maintenance and repairMaintenance Repairs and service workElectrical data and ambient conditions Fuse ReplacementElectrical data EnvironmentLeica DM750 Result if used improperly IntroductionUnpacking Ready Substage Illumination Adjustable Condenser CenteringLeica DM750 is available with two Types of Substage Illumination. Identify ToolTools used Attaching the viewing TubesϘϘ Allen key Leica EZ viewing tube with integrated eyepieces Leica EZ Viewing Tube integrated eyepiecesEyepieces Continue with the Eyecups section on Tightening the captive thumbscrew againInsert the eyepieces into the tubes Leica Standard Viewing Tube separated eyepiecesOrientation Eyecups Installing Objectives section onOrder to help block out ambient room light Installing Objectives Installing ObjectivesObjective nosepiece Ser needs to be installed Installing the Substage CondenserSubstage Condenser Thus roughly centered Set Setting the Illumination Intensity Power CordTurning on the microscope Work SurfaceDelivery package or, for a Leica DM750 Complete Condenser CenteringWith Koehler illumination, tighten Knurled screws Using the Condenser Using the Condenser Slide grips hold the slide in place Prepare to View a Specimen SlideFocusing Adjust the eyetubes Viewing Tube AdjustmentStandard Viewing Tube with One or Two Focusing Eyepieces Leica EZ Viewing TubeOn and your adjustments will be minimal Condenser focusing knob Koehler ConfigurationKoehler Configuration Oil Immersion Technique Oil Immersion Technique Changing the status of the time delay shutoff Time Delay ShutoffOr Disabled and you will not see any blinking No changes in the intensity controlLeica DM750 Manual Ready! Set! Go Care of the Microscope Instructions for cleaning General maintenanceStorage and handling Illumination Mechanical MaintenanceTroubleshooting Make sure that a DF objective is being used TroubleshootingPhase contrast Dimensions Leica DM750 Manual Leica DM750 Manual Leica DM750 Manual