RAV-Ware— Configuring System Settings

To change telephone preferences

1.In the Preferences tab, set the system to Auto-Answerafter 2 Rings or 4 Rings or select Disabled if you want to manually answer calls.

2.Select Auto-Disconnectif you would like RAV to disconnect when it detects loop- drop or call progress tones.

3.Select from three available ringer melodies.

Click Ringer Test to hear selected melody.

Figure 3.14. Telephone preferences

Note:This option is only available when you are connected to a RAV unit.

4.Select Audible Connect if you would like one tone to sound when the RAV is taken off hook and two tones to sound when the RAV is on hook.

5.Adjust ringer volume using the Ringer Level slider.

6.Enter the Local Number for the RAV

system.The local number displays on the third line of the RF Controller LCD.

RAV-Ware— Customizing RAV Components

 

35

 

Customizing RAV Components

Your RAV system is pre-configured for optimal audio quality right out of the box. However, you can customize the audio and adjust the volume to match user preferences. You can also change the mix of audio being sent to the far-end conference site and recording devices.

Microphones

You can adjust microphone volume and enable or disable ALC (automatic level control) in the Microphone Settings window. Automatic Level Control automatically adjusts microphone levels to ensure participants’ voices are transmitted at consistent levels regardless of whether people are speaking loudly or softly.

To access Microphone Settings

Click the Mic Pod icon on the Configuration screen.

To enable ALC

To select telephone configuration

1.In the Configuration tab, select the Country where the phone is being used.

2.Select the flash duration from the Flash Setting list.This setting is dependent on the requirements of your PBX or telephone provider.

Warning: The country code must be set correctly in RAV-Ware and the RF Controller to ensure that the unit operates properly and that it complies with the country’s telco requirements. Changing this code to a country other than the intended country of operation might cause the RAV to be non-compliant.

To adjust telephone volume

1.Select Receive ALC. Clearone recommends keeping Receive ALC (automatic level control) selected.This feature adjusts the far-end audio to keep it at a constant level.

2.Use the sliders to adjust the level of the telco transmit and telco receive.

Note: If you select ALC, the Telco Receive slider is disabled.

Figure 3.15. Telephone configuration

Figure 3.16. Telephone level

Click the ALC button.The indicator will turn green when ALC is enabled and the audio level sliders will be disabled.

To adjust audio level (volume)

Using the slider, adjust the volume.The meter will display output levels.

To disable Acoustic Echo Cancellation (AEC)

1.Click the Advanced button.

2.Click AEC to disable Acoustic Echo Cancellation.

Note: AEC prevents echo from reaching the far-end site.

AEC should be kept enabled for normal operation.

To disable Noise Cancellation (NC)

1.

Click Advanced.

Figure 3.17. Microphone settings

 

 

2.

Click NC to disable noise cancellation.

 

Note: Noise Cancellation prevents ambient or background noise from being sent to the far-end. ClearOne recommends keeping NC enabled.

Figure 3.18. Advanced settings

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 20
Contents Page Table of Contents Introduction Services and support RAV 600/900Product returns UnpackingMixer Product OverviewRF Radio Frequency Controller Microphone Pods Basic Room DesignBasic Room Design for RAV Speakers ceiling- or wall-mountInstallation Overview System Requirements for RAV-Ware Network InformationConnecting the RAV Audio conferencing To set up audio conferencingBasic Connections Attach the external antenna and turn it it is upright Connecting video codecs, amplifiers and sound cards Auxiliary DevicesTo connect to a video codec To connect to a sound cardConnecting VCRs and DVD players Connecting PTZ camerasConnecting for serial control Connecting for USB controlDigital phones To connect to a digital phoneRAV-Ware Software Configuration Install RAV-Ware IntroductionGetting started with RAV-Ware RAV-Ware overview RAV-Ware connections RAV-Ware filesNetwork Find Configuring System SettingsCommunication Settings Regional Settings Telephone SettingsCustomizing RAV Components MicrophonesMixer Console Effects of using an external amplifierLoudspeakers Line Input and Output Preconfigured video codecs, amplifiers and sound cardsAdjusting Line Input/Output settings Record and Playback Preconfigured record/playback devicesAdjusting Record/Playback settings Setting camera presets Camera ControlsDialer and Phonebook Usage PhonebookDialer Event Log Advanced FeaturesSystem Checks Device Toolbox Editor Error MessagesFirmware upgrades Using the RAV Using the Controller Managing CallsProgramming Phone Preferences Using the Phonebook from the RF ControllerAccessing the menu Adjusting the Settings ConfigurationTo select a frequency To perform RF radio testTo enter flash duration To change LCD contrastTo view the IP address To check the RAV versionWeb Interface Dial Accessing the web interfaceOverview To download log To open event logTo clear log To open the system checks System CheckLog Out Appendix Maintenance TroubleshootingAudio ControllerSpeakers PinoutsCamera pinouts GeneralSpecifications DimensionsSerial Commands Command structureConventions Groups and channelsMeter type definitions Serial command error codesRAV serial commands AA Auto Answer Enable/ Disable Aarings Number of Rings to Auto Answer OnAD Auto Disconnect Enable/ Disable AEC Acoustic Echo Canceller enable/ disableAecref Acoustic Echo Cancellation Reference Aconn Audible Connect / Disconnect IndicationBatterylvl Battery Level Camctrlmode Camera Control Port ModeBaud Baud Rate Calldur Call DurationCampreset Camera Preset Campresetset Camera Preset SetupCamflow Camera Control Flow Control Cammove Move the CameraCAMPRESETSET2 Camera Preset Setup Camswitchlag Camera Switch Time LagCamposition Camera Position Camtrack Camera TrackDefault Default The Unit Cleareffect Clear Effect Wide Band Telco EmulationClock Clock Set Country Country SelectionDid Device ID Device Device Identification LabelDial Dtmf Dialing Enetgate Ethernet default Gateway address Enetaddr Ethernet port IP addressEnetdhcp Ethernet Dhcp Selection Enetdnsa Ethernet DNS Server addressesEqsel Equalization Enable Gain Gain AdjustmentEQ Equalization Flow Flow ControlGreport Gate Report Hook Hook FlashHookd Hook Flash Duration Label LabelLvlreporten Level Report Enable LVL LevelLvlreport Level Report Manufacturer Manufacturer Identification LabelMiccampreset Mic Camera Preset Ncsel Noise Cancellation SelectMtrx Matrix Routing Mute MutePbdial Dial a PB Entry by Name Phonebookadd Adds an Entry to the PhonebookPhonebookcnt Queries the Number of Entries in the Phonebook Phonebookdel Deletes an Entry to the PhonebookReset Reset Redial Dial the last number againRffreq RF Frequency Selection Ring Ring IndicationSilenceprst Silence Camera Preset Ringerlvl Audible Ring LevelRingersel Audible Ring Melody Selection Ringertest Audible Ring Melody TestStereomix Sets the Input to be a Stereo Mix Syschecks System ChecksSysresult System Check Result 112TE Telco Enable Telcolvlctrl Telco TX Level Control Enable/ DisableVolume Volume Adjustment UID Unit IDElectrical Safety Advisory ComplianceFCC Part 15/ICES-003 Compliance FCC Part 68 ComplianceEuropean Compliance EC Declaration of ConformityIndex