16 | Vega’s |
7.3.1Menu 1 - Line Level Settings
This screen is displayed after a line has been selected from the Level Menu Screen. The selected line number is shown on the display and the select LED for that line continues to blink. In this example Line 1 has been selected.
PROG1 - Go to RX Input Level Screen. PROG2 - Go to LAM level setup. PROG3 - Go to Line Levels Screen. PROG4 - Return to Level Menu Screen.
7.3.1.1 RX Input Level Screen
Line 1 level adjust
RX | LAM | back |
PROG1 | PROG2 | PROG3 PROG4 |
The RX input levels serve as a master level adjustment allowing small adjustments in gain. This is a per line |
| ||||
adjustment. Typically these are left at 0 dB. |
|
|
|
|
|
| Ln1 Min Rx lvl |
| |||
|
|
| |||
PROG1 - Resets level setting to default of |
|
| up | back |
|
|
|
|
|
| |
PROG2 - Increments the level setting by 1 dBm (max of 0dB). |
|
|
|
|
|
PROG1 PROG2 | PROG3 | PROG4 |
| ||
PROG3 - Decrements the level setting by 1 dBm (min of |
|
| |||
|
|
|
|
| |
PROG4 - Return to Other Line Level Screen. |
|
|
|
|
7.3.1.2 LAM Programming Screen
This screen shows the current settings for the Line Activity Monitor for the line number shown. The
PROG1 - go to LAM Duration After Release screen. PROG2 - go to LAM Trigger Level Screen. PROG3 - Toggle Select or Unselect LAM control. PROG4 - Return to Other Line Level Screen.
7.3.1.2.1 LAM Duration After Release screen
LAM1-S 7sec -10dBm dur lvl S/U back
PROG1 PROG2 PROG3 PROG4
This parameter determines how long the LAM light will flash after the triggering signal disappears.
PROG1 - Resets duration setting to default of 7 seconds.
PROG2 - Increments the time setting by 1 second (maximum of 25sec). PROG3 - Decrements the time setting by 1 second (minimum of 0sec). PROG4 - Saves the current duration setting and returns to the LAM
Programming Screen.
7.3.1.2.2 LAM Trigger Level Screen
LAM1-S Duration 7se 7sec dwn up back
PROG1 PROG2 PROG3 PROG4
These parameters determine the audio level required to trigger the LAM function.
PROG1 - Adjusts level at which the LAM triggers.
PROG2 - Increments the level setting by 1 dBm (max of 0dBm). PROG3 - Decrements the level setting by 1 dBm (min of
Programming Screen.
LAM1-U Level -10dB -10dB dwn up back
PROG1 PROG2 PROG3 PROG4
7.3.1.3 Mute Button Level Screen
These parameters are used to set the level of Mute on a Per line bases.
PROG1 – Sets level of mute to off (total quite).
PROG3 – Go to Edit level screen.
PROG4 - Return to Level Menu Screen.
Mute1 Level | = |
OFF | edit back |
PROG1 PROG2 | PROG3 PROG4 |